Home › Philips Medical Systems Hsg › ECG Cables and Leadsets
ECG Cables and Leadsets
Philips Medical Systems Hsg · Model 5-LEAD SET, DISPOSABLE, CHEST, IEC · UDI-DI 20884838075751
DSA
Prescription
10
510(k) clearances
629
Adverse events (17 deaths)
12
Recalls
139
Facilities
Description
Philips Single-Patient-Use Disposable ECG Lead Sets are intended for use only by trained healthcare professionals for measurement of a patients ECG for both diagnostic and monitoring purposes. Use is limited by the indications for use of the connected monitoring or diagnostic equipment. These Philips lead sets are intended for short-term use only (average patient stay of 5 days). Average lifetime of 5 days for disposable products.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-01-21 | Physio-Control, Inc. | Product shipped with incorrect IFU. IFU does not include proper cleaning/disinfection instructions |
| 2022-02-03 | Volcano Corp | Multi-Modality Touch Screen Modules (MM-TSM), used with integrated IVUS systems, may crack, or become damaged, which may affect their usability. They could become non-functional. T |
| 2019-08-01 | GN Otometrics | The electrode lead connector has a protruding conductor beyond insulation of approximately 0.1 mm. |
| 2019-07-19 | Philips North America, LLC | The thickness of the connector to the trunk cable on affected limb lead sets may be greater than specified. which may prevent or impede the performance of I 2-Lead ECG measurements |
| 2019-05-10 | GE Healthcare, LLC | ECG trunk cables and leadwires may reduce the amount of energy reaching the patient during defibrillation, potentially limiting success of defibrillating the patients rhythm. |
| 2019-05-10 | GE Healthcare, LLC | ECG trunk cables and leadwires may reduce the amount of energy reaching the patient during defibrillation, potentially limiting success of defibrillating the patients rhythm. |
| 2019-05-10 | GE Healthcare, LLC | ECG trunk cables and leadwires may reduce the amount of energy reaching the patient during defibrillation, potentially limiting success of defibrillating the patients rhythm. |
| 2019-05-10 | GE Healthcare, LLC | ECG trunk cables and leadwires may reduce the amount of energy reaching the patient during defibrillation, potentially limiting success of defibrillating the patients rhythm. |
| 2019-05-10 | GE Healthcare, LLC | ECG trunk cables and leadwires may reduce the amount of energy reaching the patient during defibrillation, potentially limiting success of defibrillating the patients rhythm. |
| 2014-03-05 | Remington Medical Inc. | Remington Medical discovered an error on the FL-601-97 IFU; part number IFU-RM-0154. Specifically, the polarity for the black chuck in the picture is wrong. It shows (+), but shoul |