Home › Conmed Corporation › CONMED GOLDLINE
CONMED GOLDLINE
Conmed Corporation · Model 131318A · UDI-DI 20653405056321
GEI
Prescription
10
510(k) clearances
118,289
Adverse events (469 deaths)
644
Recalls
854
Facilities
Description
CONMED GOLDLINE ELECTROSURGICAL HANDPIECE, HAND CONTROLLED WITH UltraClean BLADE ELECTRODE, BUTTON SWITCH, SAFETY HOLSTER AND 10' (3 M) CABLE
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-18 | Olympus Corporation of the Americas | Potential labeling deficiency in which an outer shelf box is incorrectly labeled as a 37-cm device. |
| 2026-06-08 | Stryker Corporation | There has been an increased amount in reported complaints consistently describing leaking from the handpiece during use. |
| 2026-06-08 | Stryker Corporation | There has been an increased amount in reported complaints consistently describing leaking from the handpiece during use. |
| 2026-06-02 | Maquet Cardiovascular, LLC | Getinge identified that Vasoview Hemopro 2 devices from Lot 3000547797 were exposed to an out-of-specification sterilization dose during a gamma sterilization run (Run ID 1183-2878 |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-02-25 | Olympus Corporation of the Americas | Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting For |
| 2026-02-25 | Olympus Corporation of the Americas | Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting For |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docsData compiled from public U.S. FDA sources (GUDID, 510(k)/PMA, MAUDE, recalls, establishment registration). Adverse-event reports are unverified and do not establish causation. Informational only — not medical, clinical, or regulatory advice.
