Home › Seaspine Orthopedics Corporation › Atoll
Atoll
Seaspine Orthopedics Corporation · Model 16-21-1906 · UDI-DI 10889981033859
1
510(k) clearances
14,567
Adverse events (40 deaths)
68
Recalls
322
Facilities
Description
Offset Hook (right) - large. The Atoll OCT Spinal System is intended for use as an aid in spine fusion. It consists of screws, hooks, rods, and connectors. These components are available in a variety of sizes to allow for a variety of configurations to better fit each individual patient's pathology. The Atoll OCT Spinal System components are manufactured from medical implant grade titanium alloy Ti-6Al-4V (ELI) per ASTM F-136 or ISO 5832-3.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2023-02-16 | Medtronic Sofamor Danek USA Inc | Incorrect type of titanium was used which reduces the gripping strength of the screw head of 5 batches of Infinity Multi-Axial Screws |
| 2023-02-16 | Medtronic Sofamor Danek USA Inc | Incorrect type of titanium was used which reduces the gripping strength of the screw head of 5 batches of Infinity Multi-Axial Screws |
| 2023-02-16 | Medtronic Sofamor Danek USA Inc | Incorrect type of titanium was used which reduces the gripping strength of the screw head of 5 batches of Infinity Multi-Axial Screws |
| 2023-02-16 | Medtronic Sofamor Danek USA Inc | Incorrect type of titanium was used which reduces the gripping strength of the screw head of 5 batches of Infinity Multi-Axial Screws |
| 2023-02-16 | Medtronic Sofamor Danek USA Inc | Incorrect type of titanium was used which reduces the gripping strength of the screw head of 5 batches of Infinity Multi-Axial Screws |
| 2022-06-13 | K2M, Inc. | Some of the rods in this lot were observed to have discoloration, later confirmed to be indication of trace amounts of inorganic phosphorous compound. This may produce a mild irrit |
| 2022-01-13 | K2M, Inc | Stryker received two (2) complaints for units from specific lots of Inner and Outer Dilators not fitting together properly during a surgical procedure. Some dilators from these lot |
| 2022-01-13 | K2M, Inc | Stryker received two (2) complaints for units from specific lots of Inner and Outer Dilators not fitting together properly during a surgical procedure. Some dilators from these lot |
| 2020-03-26 | Medtronic Sofamor Danek USA Inc | Nonconforming product; length of the product measured shorter than the labeled length. |
| 2020-01-28 | Medicrea International | An internal component was assembled in the incorrect orientation, which may lead to the tulip head disengaging from the crew shank during or after screw insertion, or during the re |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.