xCupTM
ESCREEN, INC. · Model DUE-1117X-071-01 · UDI-DI 10867802000273
Description
The xCupTM for use with the xReaderTM is for in vitro diagnostic use and is intended for prescription use in laboratories, point-of-care and workplaces by trained users. The test is not intended for over-the-counter use. The test device cannot be read visually and must be used with the xReaderTM. The xCupTM qualitatively detects drug classes in human urine at the following cut-off concentrations: Amphetamines at 500 ng/ml; Barbiturates at 300 ng/mL; Benzodiazepines at 300 ng/mL; Cocaine at 150 ng/mL; Methamphetamines at 500 ng/mL; Methadone at 300 ng/mL; Morphine at 300 ng/mL and 2000 ng/mL; Oxycodone at 100 ng/mL; Phencyclidine at 25 ng/mL; and Marijuana at 50 ng/mL. Configurations of the xCupTM may consist of any combination of the listed drug analytes. The xCupTM only provides a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography / mass spectrometry (GC/MS), high performance liquid chromatography (HPLC) or liquid chromatography / tandem mass spectrometry (LC/MS/MS) are the preferred confirmatory methods. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are obtained.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2020-07-13 | OraSure Technologies, Inc. | Incorrect lot number for Standard Oral Fluid Negative Calibrator on specification sheet included in kit and/or additionally same error on unit box |
| 2020-07-13 | OraSure Technologies, Inc. | Incorrect lot number for Standard Oral Fluid Negative Calibrator on specification sheet included in kit and/or additionally same error on unit box |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |
| 2015-11-16 | Ameditech Inc | Ameditechs Drugs of Abuse Tests listed above have shown reduced reactivity for up to two (2) of the nineteen (19) Benzodiazepine (BZO) compounds for which specificity information i |