Multi Level Black Belt Set
KOROS U.S.A., INC. · Model 7325-50 · UDI-DI 10840199503558
Description
Multi Level Black Belt Set Consists of the Following: 1x 7325-51 - Retractor, Right, 1x 7325-52 - Retractor, Left, 1x 7325-53 - Triple Blade Retractor Right for wide blades, 1x 7325-54 - Triple Blade Retractor Left for wide blades, 1x 7325-58 - Depth Gauge, 4x 7325-60 - 55 mm standard width blunt blade colored anodized, 4x 7325-61 - 60 mm standard width blunt blade colored anodized, 4x 7325-62 - 65 mm standard width blunt blade colored anodized, 4x 7325-63 - 70 mm standard width blunt blade colored anodized, 4x 7325-70 - 55 mm standard width prong blade colored anodized, 4x 7325-71 - 60 mm standard width prong blade colored anodized, 4x 7325-72 - 65 mm standard width prong blade colored anodized, 4x 7325-73 - 70 mm standard width prong blade colored anodized, 4x 7325-84 - 55 mm x 40 mm wide blunt blade colored anodized, 4x 7325-81 - 60 mm x 40 mm wide blunt blade colored anodized, 4x 7325-82 - 65 mm x 40 mm wide blunt blade colored anodized, 4x 7325-83 - 70 mm x 40 mm wide blunt blade colored anodized, 4x 7325-90 - 55 mm x 40 mm wide prong blade colored anodized, 4x 7325-91 - 60 mm x 40 mm wide prong blade colored anodized, 4x 7325-92 - 65 mm x 40 mm wide prong blade colored anodized, 4x 7325-93 - 70 mm x 40 mm wide prong blade colored anodized, 2x 7320-40 - Black Belt Blade Inserter Clamp, 1x 7325-59 - Instrument Tray
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2018-06-19 | Nico Corp. | Mislabeled hook pouch included a transport/storage label rather than the product label containing key product information such as part number, lot number, and expiration date, etc |
| 2012-08-21 | Vycor Medical, Inc. | Vycor Medical recalled their VBAS (Vycor Viewsite Brain Access System) because an unidentified black fiber was found on the device. |
| 2012-07-17 | Nico Corp. | BrainPath sheaths were mislabeled. Sheaths which measure 50mm were labeled as 60mm. The length callout on the label does not match the actual length of the sheath within the packag |
| 2012-07-17 | Nico Corp. | BrainPath sheaths were mislabeled. Sheaths which measure 50mm were labeled as 60mm. The length callout on the label does not match the actual length of the sheath within the packag |
| 2007-12-19 | Abbott Spine | Dislodged Collar Spring; The collar spring binding on the shaft of generic handle used with multiple surgical instruments has the potential to release the device's internal bearing |
| 2003-02-26 | Ohio Medical Instrument Co Inc | The component was manufactured with an insufficient weld that could break during use. |