Description

NuMed Silver Alginate 4x5 Dressing, conformable wound dressings with a high mannuronic acid content. The silver impregnated alginate fibers, 1.4% w/w silver as silver calcium alginate per dressing, forms a gel when in contact with wound exudate or blood, which creates a moist wound healing environment. The silver in the alginate wound dressing has an antibacterial effect on various types of bacteria including; Staphylococcus aureus and E coli. The sustained release of silver ions protects the dressing from a broad spectrum of bacterial contamination over a period of up to 3 days.

Recalls

DateFirmReason
2026-06-08ConvaTec, IncSurgical dressing manufactured out of specification (greater thickness).
2026-04-27Oculus Technologies of Mexico, S.A. de C.V.The recall is being conducted due to corrosion of the internal metallic spring within the sprayer component. This condition is caused by material incompatibility between the produc
2026-01-16Integra LifeSciences Corp. (NeuroSciences)Potential packaging failures, which could lead to a breach in the sterile barrier.
2026-01-16Integra LifeSciences Corp. (NeuroSciences)Potential packaging failures, which could lead to a breach in the sterile barrier.
2026-01-16Integra LifeSciences Corp. (NeuroSciences)Potential packaging failures, which could lead to a breach in the sterile barrier.
2026-01-05Medline Industries, LPMedline has identified that the manufacturer of the sterile saline wound wash may not have manufactured products to meet the minimum required sterility assurance level required for
2026-01-05Medline Industries, LPMedline has identified that the manufacturer of the sterile saline wound wash may not have manufactured products to meet the minimum required sterility assurance level required for
2025-08-05Integra LifeSciences Corp. (NeuroSciences)Packaging failures were identified which could lead to a breach in the sterile barrier.
2025-08-05Integra LifeSciences Corp. (NeuroSciences)Packaging failures were identified which could lead to a breach in the sterile barrier.
2025-08-05Integra LifeSciences Corp. (NeuroSciences)Packaging failures were identified which could lead to a breach in the sterile barrier.