Integra® Total Foot System"
Ascension Orthopedics, Inc. · Model TFSFOREFTIMP · UDI-DI 10381780064589
Description
The Integra Total Foot System is a system containing bone plates and screws designed for use in the skeletally mature foot. The plates and screws are intended to be used for stabilization and fixation of fresh fractures, intra-articular and extra-articular fractures, joint depression and multi-fragmentary fractures. The subject devices can also be used in revision procedures, joint fusion, and in reconstructing the small bones of the feet. Implants are manufactured from Titanium Alloy. The instrumentation is manufactured from biocompatible materials. The fore foot plates include open wedge plates, universal forefoot plates, MPJ fusion plates, and tarsalis plates.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-04-24 | Medartis AG | The cannulation of the CCS screw is not centered. |
| 2026-01-23 | I.T.S. GmbH | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). |
| 2026-01-23 | I.T.S. GmbH | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). |
| 2026-01-09 | Medartis AG | Mix up between specified lots of 2.5mm and 2.8mm outer diameter screws. |
| 2026-01-09 | Medartis AG | Mix up between specified lots of 2.5mm and 2.8mm outer diameter screws. |
| 2025-11-24 | Smith & Nephew, Inc. | Removal of affected lot of screws due to labeling error. |
| 2024-04-12 | Medartis Inc. | Screw is 16mm long instead of 22mm long. |
| 2024-03-20 | Zimmer, Inc. | Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user sinc |
| 2024-03-20 | Zimmer, Inc. | Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user sinc |
| 2024-03-20 | Zimmer, Inc. | Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user sinc |