Labomed Prima ENT microscope with Motorized fine focus
LABOTECH MICROSCOPES INDIA PRIVATE LIMITED · Model 6137000-100 · UDI-DI 08908006463015
Description
Prima ENT microscope with Motorized fine focus - MaxLite(TM) optics, 5 step magnification: 0.4x, 0.6x, 1.0x, 1.6x, 2.5x - 50W LED coaxial illumination (cold light), 100V-240V AC universal power supply - Straight binocular head, IPD 50-75mm - f=250mm CMO with manual fine focus knob and sterilizable cap - WF 10x/18mm eyepieces with diopter lock and foldable eyeguard - Swivel arm (525mm Long, 360 degree rotation) and suspension arm (600mm Long, 320 degree rotation) with locking/tension control knobs and LED shut-off in park position - Carrier arm and 120 degree coupling with tension adjustment locks, T-handle /Ergo Handle control - Floor stand with H-shape base on castor wheels with brakes - Yellow and Green sliding filters, dust cover, and sterilizable knob caps
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2024-05-13 | Aesculap Inc | Possibility of the robotic arm to drop more than 10cm from its original position after pressing the emergency stop button due to failure of the integrated safety mechanism. |
| 2023-08-18 | Carl Zeiss Suzhou Co., Ltd. | Surgical microscope for use in ophthalmology may be missing a screw from the suspension arm, which may cause the suspended components to fall from the suspension arm, which may inj |
| 2022-08-26 | Leica Microsystems, Inc. | During internal testing, Leica Microsystems has become aware of a component change on the photodiodes inside the M530 Optics Carrier which will result in an inaccurate adjustment o |
| 2022-08-26 | Leica Microsystems, Inc. | During internal testing, Leica Microsystems has become aware of a component change on the photodiodes inside the M530 Optics Carrier which will result in an inaccurate adjustment o |
| 2022-08-26 | Leica Microsystems, Inc. | During internal testing, Leica Microsystems has become aware of a component change on the photodiodes inside the M530 Optics Carrier which will result in an inaccurate adjustment o |
| 2022-08-26 | Leica Microsystems, Inc. | During internal testing, Leica Microsystems has become aware of a component change on the photodiodes inside the M530 Optics Carrier which will result in an inaccurate adjustment o |
| 2022-07-14 | Aesculap Implant Systems LLC | Application error problems: Rebalance scope message: 1.Rebalancing process 2.Usage of Robot Recovery: 3. Autofocus not available: |
| 2021-11-03 | Leica Microsystems, Inc. | In May 2021, Leica Microsystems received one (1) complaint pertaining to the M220 F12 Surgical Microscope system. There was no patient injury reported for this complaint. However, |
| 2021-02-19 | Aesculap Implant Systems LLC | Malfunction of the robotic arm preventing further movement of the robotic arm and requiring restart of the robotic digital microscope system. |
| 2016-01-11 | Leica Microsystems, Inc. | An electronic component of the Leica M525 OH4 and Leica M720 OH5 surgical microscopes with 400W illumination could potentially overheat, resulting in smoke and smell emanating from |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs