1
510(k) clearances
9,183
Adverse events (30 deaths)
115
Recalls
422
Facilities

Description

The GS Medical PYXIS 3D Titanium Cervical Cage System devices are designed for restoring the height of the intervertebral space after resection of the disc. The intervertebral body fusion devices are made of 3D printed titanium alloy (Ti-6Al-4V) in accordance with and manufactured as per ASTM F3001. The material and manufacturing process of the subject device, PYXIS 3D Titanium Cervical Cage is identical to the additional predicate (PYXIS 3D Titanium Cage System, K223868). The PYXIS 3D Titanium Cervical Cage System implants are available in various heights, footprints, and lordotic angles to suit the individual patient’s pathology and anatomical conditions. The subject device cages ranging in height from 5mm-10mm in 1 mm increments with 0°, 4°, and 8° options. Also in 4.5mm hight for the 0° angle. The cages are provided in three distinct footprints.

Recalls

DateFirmReason
2025-11-03Orthofix U.S. LLCLabeling contains claims that are not consistently present.
2025-11-03Orthofix U.S. LLCLabeling contains claims that are not consistently present.
2025-10-29Medicrea InternationalDue to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant.
2025-10-29Medicrea InternationalDue to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant.
2025-09-16Medtronic Sofamor Danek USA IncExpandable interbody system cage may loose height or collapse (loss of lordosis), which could result in migration, subsidence and/or neurological injury. Therefore, surgical techni
2025-08-06SEASPINE ORTHOPEDICS CORPORATIONInserter, used as part of a system with an intervertebral body fusion device, may contribute to difficulty disengaging the implant or improper implant positioning, which may may le
2025-06-24Orthofix U.S. LLCA 37 mm implant width intervertebral body fusion device has a labeling discrepancy with incorrect width of 33 mm stated on the outer label side flap and inner label side flap infor
2025-02-20Orthofix U.S. LLCThe product is mislabeled with the incorrect anterior height of 10mm, but the laser marking on the implant and corresponding trial both show the correct anterior height of 10.5mm.
2024-12-15Alphatec Spine, Inc.Complaints have been received regarding post-operative implant collapse.
2024-08-14Innovasis, IncDue to interfacing issues between the implant trial and inserter of the lumbar intervertebral fusion device.