Description
"The GS Medical AnyPlus PEEK Lumbar Cage device consists of implants available in various heights and lordotic configurations with an open architecture to accept packing of bone graft material. The implants are made of polyether-ether-ketone (PEEK OPTIMA LT1) (Manufacturer – INVIBIO) body (PEEK conforming to ASTM F2026) with the x-ray markers made of Tantulum (conforming to ASTM F560). The AnyPlus PEEK Lumbar Cage is indicated for use with autogenous bone graft in skeletally mature patients with degenerative disc disease (""DDD"") at one or two contiguous spinal levels from L2-S1. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The AnyPlus PEEK Lumbar Cage is to be combined with internal supplemental fixation cleared for use in the lumbar spine."
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-10-29 | Medicrea International | Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. |
| 2025-10-29 | Medicrea International | Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. |
| 2025-09-16 | Medtronic Sofamor Danek USA Inc | Expandable interbody system cage may loose height or collapse (loss of lordosis), which could result in migration, subsidence and/or neurological injury. Therefore, surgical techni |
| 2025-08-06 | SEASPINE ORTHOPEDICS CORPORATION | Inserter, used as part of a system with an intervertebral body fusion device, may contribute to difficulty disengaging the implant or improper implant positioning, which may may le |
| 2025-06-24 | Orthofix U.S. LLC | A 37 mm implant width intervertebral body fusion device has a labeling discrepancy with incorrect width of 33 mm stated on the outer label side flap and inner label side flap infor |
| 2025-02-20 | Orthofix U.S. LLC | The product is mislabeled with the incorrect anterior height of 10mm, but the laser marking on the implant and corresponding trial both show the correct anterior height of 10.5mm. |
| 2024-12-15 | Alphatec Spine, Inc. | Complaints have been received regarding post-operative implant collapse. |
| 2024-08-14 | Innovasis, Inc | Due to interfacing issues between the implant trial and inserter of the lumbar intervertebral fusion device. |