The subject device, the QUASAR Standalone ACIF System cages are designed for restoring the height of the intervertebral space after resection of the disc while also providing biomechanical stability with the addition on an integrated plate. This integrated plate allows for the user to bypass using an additional plate as seen with traditional ACIF spacers. The QUASAR Standalone ACIF System devices consist of implants available in various heights and lordotic configurations with an open architecture to accept packing of bone graft material. The supplementary fixation screws are used along with the subject device cage and plate. The intervertebral body fusion devices are made of hydroxyapatite polyether-ether-ketone (HA PEEK OPTIMA LT1) body with Titanium alloy plates (Ti-6Al-4V) and supplementary screws made up of Titanium alloy (Ti-6Al-4V).
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-10-29 | Medicrea International | Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. |
| 2025-10-29 | Medicrea International | Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. |
| 2025-09-16 | Medtronic Sofamor Danek USA Inc | Expandable interbody system cage may loose height or collapse (loss of lordosis), which could result in migration, subsidence and/or neurological injury. Therefore, surgical techni |
| 2025-08-06 | SEASPINE ORTHOPEDICS CORPORATION | Inserter, used as part of a system with an intervertebral body fusion device, may contribute to difficulty disengaging the implant or improper implant positioning, which may may le |
| 2025-06-24 | Orthofix U.S. LLC | A 37 mm implant width intervertebral body fusion device has a labeling discrepancy with incorrect width of 33 mm stated on the outer label side flap and inner label side flap infor |
| 2025-02-20 | Orthofix U.S. LLC | The product is mislabeled with the incorrect anterior height of 10mm, but the laser marking on the implant and corresponding trial both show the correct anterior height of 10.5mm. |
| 2024-12-15 | Alphatec Spine, Inc. | Complaints have been received regarding post-operative implant collapse. |
| 2024-08-14 | Innovasis, Inc | Due to interfacing issues between the implant trial and inserter of the lumbar intervertebral fusion device. |