PYXIS 3D Titanium Cervical Cage, Close
GS Medical Co., Ltd. · Model 0905-5560 · UDI-DI 08800322757635
Description
The AnyPlus Spinal Fixation System consists of various hooks, screws, rods and connectors and is intended to create a rigid spinal construct. The components are manufactured from Ti6AI4V ELI according to ISO 5832-3 and ASTM F-136. The rods are also manufactured from Cobalt Chromium according to F1537-11. The screws are available from 4.0 to 10.5mm diameters with lengths ranging from 20 to 100mm (Length does not include the screw head). Specialized instruments are available for the application and removal of the Anypluss Spinal Fixation System. AnyPlus Spinal Fixation System are non-cervical spinal fixation devices intended for use as posterior pedicle screw fixation systems (T1 -S2), a posterior hook fixation system (T 1-5), or as a anterolateral fixation system (T8-L_5). All components in the system are limited to skeletally mature patients. System components are to be used for immobilization and stabilization of the spine as an adjunct to fusion. These devices are indicated for all of the following indications regardless of the intended use: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis, Scheuermann's Disease), tumor, stenosis, pseudoarthrosis, and failed previous fusion.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-10-29 | Medicrea International | Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. |
| 2025-10-29 | Medicrea International | Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. |
| 2025-09-16 | Medtronic Sofamor Danek USA Inc | Expandable interbody system cage may loose height or collapse (loss of lordosis), which could result in migration, subsidence and/or neurological injury. Therefore, surgical techni |
| 2025-08-06 | SEASPINE ORTHOPEDICS CORPORATION | Inserter, used as part of a system with an intervertebral body fusion device, may contribute to difficulty disengaging the implant or improper implant positioning, which may may le |
| 2025-06-24 | Orthofix U.S. LLC | A 37 mm implant width intervertebral body fusion device has a labeling discrepancy with incorrect width of 33 mm stated on the outer label side flap and inner label side flap infor |
| 2025-02-20 | Orthofix U.S. LLC | The product is mislabeled with the incorrect anterior height of 10mm, but the laser marking on the implant and corresponding trial both show the correct anterior height of 10.5mm. |
| 2024-12-15 | Alphatec Spine, Inc. | Complaints have been received regarding post-operative implant collapse. |
| 2024-08-14 | Innovasis, Inc | Due to interfacing issues between the implant trial and inserter of the lumbar intervertebral fusion device. |