RADI CHAMP260
KH Medical Co., Ltd. · Model KM002 · UDI-DI 08800204300096
Description
The RADI CHAMP260 is a stand-alone automated isothermal amplification and detection system for target nucleic acid sequences found in human specimens. The instrument is used in conjunction with KH Medical’s LOOP-Mediated Amplification in vitro diagnostic products. RADI CHAMP260 is designed to freely manipulate specific temperature and running time for amplification of samples by 7 inch touch screen. Amplification of target DNA occurs during the heat cycle and results in the formation of precipitate detected by the RADI CHAMP260 optics system. The precipitate generated by the presence of amplified target DNA leads to a turbid Sample/Control reaction solution which is then measured by absorbance. The RADI CHAMP260 uses the change in turbidity of each Sample/Control reaction solution to report assay results as INVALID, POSITIVE, or NEGATIVE on the 7 inch touch screen.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-03-20 | Abbott Molecular, Inc. | The design of the Alinity m System Solutions drawer enclosure may allow liquid (liquid waste or system solutions) originating in the System Solutions drawer to flow beyond the foot |
| 2024-12-10 | Biocartis Nv | False-positive MSI-H results generated by the Idylla MSI Test. |
| 2024-03-20 | Abbott Molecular, Inc. | The Alinity m System camera detects whether tubes are "capped." If the camera detects a cap and the retention bar is not present on the sample rack, the system will generate the me |
| 2024-02-01 | Abbott Molecular, Inc. | Products that were intended for export only which were not approved or registered in accordance with U.S. specifications were shipped to U.S. customers. |
| 2023-12-15 | Hologic, Inc. | Due to potential false positive Flu B results when a sample was also SARS-CoV-2 positive. |
| 2023-06-14 | DiaSorin Molecular LLC | There is a potential for the direct amplification disc to malfunction which may result in spillage of liquid from the disc. |
| 2022-12-09 | Abbott Molecular, Inc. | The firm identified the following three potential issues which may have impacted ADUs installed on distributed Alinity m Systems. 1. Systems which had their ADUs serviced may have |
| 2022-11-11 | Abbott Molecular, Inc. | The instrument was found to be installed without plunger assemblies in the clamp bar for an Amplification Detection Unit. After correction of the issue, the instrument was returne |
| 2022-10-12 | Abbott Molecular, Inc. | Abbott has identified potential performance issues for the Alinity m System software version 1.6.5: 1) In a unique scenario, the waste chute flapper was found to not open when th |
| 2022-06-22 | Meridian Bioscience Inc | When a run is aborted, the cooling period protection does not occur and the user is able to open the lid prior to the completion of the cooling period, exposing the user to heated |