OSUNG MND
OSUNG MND Co., Ltd. · Model BTIDH09 · UDI-DI 08800075611253
Description
A hand-held manual surgical instrument designed to attach to the proximal end of a surgical instrument (e.g., a screwdriver shaft) to allow the surgeon to perform manipulations with the instrument, such as manual rotation of a bone screw, reamer, dental implant, mucotome, or soft-tissue coring punch; it does not include a torque-limiting function. The device is typically made of metal and/or synthetic material and may have a straight or T-shaped handle grip which may include additional features such as a ratchet mechanism to allow the surgeon to maintain a constant hold on the handle when providing rotation in one direction. This is a reusable device.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-01-06 | Straumann USA LLC | The mix up of the impression caps provided in the package. The provided impression caps are magenta instead of brown. |
| 2025-07-24 | Dentsply IH, Inc. | The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr |
| 2025-07-24 | Dentsply IH, Inc. | The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr |
| 2025-04-14 | Prismatik Dentalcraft, Inc. | Due to packaging mix up. Package of finished devices were reported to have an incorrect finished device package inside. |
| 2025-03-08 | Straumann USA LLC | The devices are missing the laser marked depth markings. |
| 2024-06-25 | Preat Corp | Due to a manufacturing issue, the product has a out of specification rotation of the digital analog used to visually inspect dental abutments and restorations. |
| 2024-01-24 | Thommen Medical AG | The depth of the internal canal was not manufactured according to specifications. Thus, the impression coping cannot be firmly connected to the implant. |
| 2023-12-27 | TruAbutment Inc. | Retroactive: Due to defect and quality issues dental scanner may not scan properly/accurately |
| 2021-07-26 | Paltop Advanced Dental Solutions Ltd | Some devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng |
| 2021-07-26 | Paltop Advanced Dental Solutions Ltd | Some devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs