OSUNG MND
OSUNG MND Co., Ltd. · Model BSWDTL · UDI-DI 08800075611246
Description
A non-powered tool intended to fit into a screw head (e.g., slotted, cross/hex head) for the application of rotation to introduce/remove a screw (e.g., craniofacial bone screw, dental screw) into/from a patient in association with a surgical procedure [e.g., orthopaedic, dental, computer assisted surgery (CAS), image registration]. It may also be used to connect/disconnect a device to/from another device attached to a patient (e.g., implant component, fiducial marker). The proximal end of the device may have a handle for manual use or a profiled tang that fits into an independent chuck or power driver; it is typically made of metallic and/or polymer materials. This is a reusable device.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-01-06 | Straumann USA LLC | The mix up of the impression caps provided in the package. The provided impression caps are magenta instead of brown. |
| 2025-07-24 | Dentsply IH, Inc. | The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr |
| 2025-07-24 | Dentsply IH, Inc. | The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr |
| 2025-04-14 | Prismatik Dentalcraft, Inc. | Due to packaging mix up. Package of finished devices were reported to have an incorrect finished device package inside. |
| 2025-03-08 | Straumann USA LLC | The devices are missing the laser marked depth markings. |
| 2024-06-25 | Preat Corp | Due to a manufacturing issue, the product has a out of specification rotation of the digital analog used to visually inspect dental abutments and restorations. |
| 2024-01-24 | Thommen Medical AG | The depth of the internal canal was not manufactured according to specifications. Thus, the impression coping cannot be firmly connected to the implant. |
| 2023-12-27 | TruAbutment Inc. | Retroactive: Due to defect and quality issues dental scanner may not scan properly/accurately |
| 2021-07-26 | Paltop Advanced Dental Solutions Ltd | Some devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng |
| 2021-07-26 | Paltop Advanced Dental Solutions Ltd | Some devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng |