FDA Device Intelligence
HomeOSUNG MND Co., Ltd. › OSUNG MND

OSUNG MND

OSUNG MND Co., Ltd. · Model IDH5-15N · UDI-DI 08800075610652

NDP
4
510(k) clearances
4,902
Adverse events
57
Recalls
530
Facilities

Description

A hand-held dental tool intended for the manual application of rotation to tighten/loosen/remove a device [e.g., dental implant, spatial marker (localizer/tracker/calibrator)] fitted into or close to the oral cavity, and/or to a surgical instrument, in association with a dental surgical procedure [e.g., dental guided surgery registration]. It may have a built-in ratchet function, with forward and reverse direction, and a calibrated scale to which a recommended torque can be set; it is not a screwdriver. It is typically made of metallic or polymer materials and may have a standard socket connection to accommodate different tool bits/adaptors. This is a reusable device.

Recalls

DateFirmReason
2026-01-06Straumann USA LLCThe mix up of the impression caps provided in the package. The provided impression caps are magenta instead of brown.
2025-07-24Dentsply IH, Inc.The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr
2025-07-24Dentsply IH, Inc.The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr
2025-04-14Prismatik Dentalcraft, Inc.Due to packaging mix up. Package of finished devices were reported to have an incorrect finished device package inside.
2025-03-08Straumann USA LLCThe devices are missing the laser marked depth markings.
2024-06-25Preat CorpDue to a manufacturing issue, the product has a out of specification rotation of the digital analog used to visually inspect dental abutments and restorations.
2024-01-24Thommen Medical AGThe depth of the internal canal was not manufactured according to specifications. Thus, the impression coping cannot be firmly connected to the implant.
2023-12-27TruAbutment Inc.Retroactive: Due to defect and quality issues dental scanner may not scan properly/accurately
2021-07-26Paltop Advanced Dental Solutions LtdSome devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng
2021-07-26Paltop Advanced Dental Solutions LtdSome devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng