VARO Plan Software is a stand-alone Windows-based software application to support the treatment planning for dental implantation. It is designed for qualified dental practitioners, including dentists and lab technicians. The software imports the medical image dataset of the patient in DICOM format from medical CT or dental CBCT scanners for pre-operative planning and simulation of dental placement. It is intended for use as pre-operative planning software for the placement of dental implant(s) based on imported CT image data, optionally aligned to an optical 3D surface scan. Virtual Crowns can be used for optimized implant positioning under the prosthetic aspect. The digital three dimensional model of a surgical guide for a guided surgery can be designed based on the approved implant position. This 3D data can be exported to manufacture a separate physical product. Indications of the dental implants do not change with guided surgery compared to conventional surgery. Use of the software requires that the user has the necessary medical training in implantology and surgical dentistry.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-07-22 | Merge Healthcare, Inc. | Software issue may cause measurements to be displayed inaccurately. |
| 2026-07-22 | FUJIFILM Healthcare Americas Corporation | Software issue may cause the ruler measurement to be inaccurate. |
| 2026-06-30 | Merge Healthcare, Inc. | Merge Healthcare has identified a potential issue that may cause thumbnails from a previously opened patient study to be displayed in the Thumbnail Bar while a different patient st |
| 2026-06-30 | Merge Healthcare, Inc. | Merge Healthcare has identified a potential issue that may cause thumbnails from a previously opened patient study to be displayed in the Thumbnail Bar while a different patient st |
| 2026-06-19 | Boston Scientific Corporation | Software anomaly occurs when a user adds one or more vials to the cart and subsequently returns to the Activity Calculator to modify one or more input. When a user modifies an inpu |
| 2026-05-08 | GE Medical Systems SCS | GE HealthCare has become aware of a context synchronization issue in AW Server 3.2 ext. 6.5. When a user selects a patient or exam in the AW Server Web Client worklist and launches |
| 2026-03-19 | PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. | Potential safety issue involving the Mean Aneurysm Flow Amplitude (MAFA) ratio of AneurysmFlow (Interventional Tool). Philips has determined that the MAFA ratio does not provide re |
| 2026-03-05 | PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. | Potential that mis-ordered frames in Vue Motion during dynamic cine runs may cause images frames to display out of sequence. |
| 2026-01-30 | GE Medical Systems, LLC | There is a potential cybersecurity vulnerability affecting certain versions of Centricity Universal Viewer. User login credentials may be exposed on the local client workstation, w |
| 2026-01-30 | GE Medical Systems, LLC | There is a potential cybersecurity vulnerability affecting certain versions of Centricity Universal Viewer. User login credentials may be exposed on the local client workstation, w |