NOABLE LASER
Daeju Medi Tech Engineering · Model 1.0 · UDI-DI 08800017500195
Description
NOABLE LASER is a laser surgical instrument used during treatment where the laser 1450nm wavelength generated from the diode laser module. It can be used for incision, destruction and removal of skin tissue by illuminating a 1450 nm wavelength laser on the skin tissue. Based on state-of-the-art diode laser technology, the system offers many advantages, including the combination of the effective wavelengths, excellent pulse characteristics, and unique dynamic cooling device (DCD) and compact instrument. Laser is sent out through the diode laser module equipped inside the Main body to oscillate the laser, and the user uses the touch LCD in the Main body and hand-piece to set the output parameters while controlling laser radiation through the foot switch and hand-piece switch. At this point, a coolant is sprayed from the end of the hand- piece to protect skin from the heat generated by the radiated laser, resulting in a reduction in skin irritation and pain.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-06 | Lutronic Corporation | Utilizing higher fluences at 1064nm wavelength with current cryogen parameters may result in a spark/loud noise during treatment, potentially resulting in patient burn. |
| 2026-05-05 | IPG Medical Corporation | Software anomaly that causes a false display of error code 5018. |
| 2026-02-27 | Olympus Corporation of the Americas | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl |
| 2026-02-27 | Olympus Corporation of the Americas | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl |
| 2026-01-27 | Lutronic Corporation | Reports of devices sparking/popping and potentially burning patients. |
| 2025-12-15 | LEASEIR TECHNOLOGIES SLU | The console label for affected devices is missing the "DANGER" symbol. |
| 2025-07-22 | LUMENIS, LTD. | The potential for unsterilized product within finished product labeled as sterile. |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |