Liofilchem Mic Test Strip (MTS)
LIOFILCHEM SRL · Model Levofloxacin LEV 0.002-32 μg/mL 1 Strip · UDI-DI 08055182872565
Description
MTS™ (MIC Test Strip) Levofloxacin 0.002-32 μg/mL is a quantitative method intended for the in vitro determination of antimicrobial susceptibility of bacteria. MTS™ consists of specialized paper impregnated with a pre-defined concentration gradient of an antimicrobial agent, which is used to determine the minimum inhibitory concentration (MIC) in μg/mL of antimicrobial agents against bacteria as tested on agar media using overnight incubation and manual reading procedures. MTS™ Levofloxacin at concentrations of 0.002-32 μg/mL should be interpreted at 16-20 hours of incubation. MTS™ Levofloxacin can be used to determine the MIC of levofloxacin against the following bacteria. Levofloxacin has been shown to be active both clinically and in vitro against these bacterial species according to the FDA drug approved label: Gram-negative bacteria Enterobacter cloacae Escherichia coli Klebsiella pneumoniae Proteus mirabilis Pseudomonas aeruginosa Serratia marcescens Levofloxacin has been shown to be active in vitro only against the non-fastidious bacteria listed below according to the FDA drug approved label: Citrobacter freundii Citrobacter koseri Klebsiella aerogenes Klebsiella oxytoca Morganella morganii Proteus vulgaris Providencia rettgeri Providencia stuartii
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-05-01 | Remel, Inc | Product may have an off color affecting perfomance |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs