THD SLIDE ONE
THD SPA · Model THD OPTI-FIBER (REVO/BT) · UDI-DI 08033737710777
Description
The THD 880012 sterilizable flexible fibre optic cable is to be used in conjunction with the THD Slide disposable kit and the THD disposable diagnostic devices. One end of the cable has a cylindrical anodised aluminium attachment for connection to the light source of the generator (THD Evolution / THD Revolution) and other THD light sources; the other end has a curved stainless steel tip exclusively for THD anoscopes. The cable has an external silicon sheath and an internal reinforcement to prevent damaging the optical fibres. The length of the cable and its extreme flexibility allow the user to easily and comfortably use the instrument.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2023-02-10 | Unetixs Vascular, Inc. | The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism. |
| 2023-02-10 | Unetixs Vascular, Inc. | The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism. |
| 2023-02-10 | Unetixs Vascular, Inc. | The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism. |
| 2023-02-10 | Unetixs Vascular, Inc. | The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism. |
| 2017-06-09 | Natus Neurology Inc | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood |
| 2017-06-09 | Natus Neurology Inc | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood |
| 2017-06-09 | Natus Neurology Inc | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood |
| 2017-06-09 | Natus Neurology Inc | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs