Home › MPS Micro Precision Systems AG › Adjustable drill guide, Ø3.2 mm, 25° to 65°
Adjustable drill guide, Ø3.2 mm, 25° to 65°
MPS Micro Precision Systems AG · Model T5011 · UDI-DI 07640187913644
FZX
Prescription
10
510(k) clearances
8,516
Adverse events (4 deaths)
29
Recalls
524
Facilities
Description
A hand-held re-usable surgical device designed to simultaneously direct the placement and angle of the drill hole and protect the surrounding tissue. It is cannulated to accept a dedicated drill bit size and has a serrated distal end to allow firm placement on the bone. The variable angle is from 25° to 65°.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2023-11-30 | Waldemar Link GmbH & Co. KG (Mfg Site) | Mislabeled: Angle and height of the device marked as L(large) corresponds to the small/medium dimensions due to a product mix-up. This may result in too little bone material resec |
| 2022-10-10 | Hologic, Inc | IFU was not provided with the Sizer Set sterilization tray Revised Sterilization Instructions for Sizer Set |
| 2019-08-21 | Zimmer Biomet, Inc. | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. |
| 2019-08-21 | Zimmer Biomet, Inc. | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. |
| 2019-08-21 | Zimmer Biomet, Inc. | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. |
| 2018-03-26 | Zimmer Biomet, Inc. | Potential failure of sterile packaging seal. |
| 2017-08-07 | Synthes, Inc. | May have difficulty attaching the drill sleeve to the plate. If the drill sleeve will not connect to the plate intraoperatively, surgical delay could occur. If the pilot hole is dr |
| 2017-04-25 | Cook Inc. | reprocessing instructions do not provide sufficient detailed information for the cleaning, disinfection, and sterilization of these products |
| 2016-08-09 | Zimmer Biomet, Inc. | Old revisions and new revisions of the soft tissue sleeve and recon targeting arm are not interchangeable, as the new revision tissue sleeve will not fit into the old revision targ |
| 2016-06-07 | Synthes (USA) Products LLC | DePuy Synthes is initiating a voluntary medical device recall due to Blade/Screw Guide Sleeves (Part # 03.037.017) may have been manufactured with a slightly larger than specified |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.