HomeO-Two Medical Technologies Inc › CAREvent ALS

CAREvent ALS

O-Two Medical Technologies Inc · Model 01CV3100 · UDI-DI 07540195025110

BTL Prescription
1
510(k) clearances
4,749
Adverse events (34 deaths)
29
Recalls
47
Facilities

Description

CAREvent ALS kit 01CV3100 contains a CAREvent ALS resuscitator and a pressure regulator. CAREvent ALS hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of providing artificial ventilation during respiratory and cardiac arrest. The CAREvent ALS delivers automatic ventilation with controlled flow rates, airway pressure, tidal volume and frequencies. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. In addition, CAREvent ALS allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume.

Recalls

DateFirmReason
2024-12-10Mercury Enterprises, Inc. dba Mercury MedicalGas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and
2024-08-30Mercury Enterprises, Inc. dba Mercury MedicalManual resuscitator circuit flow controller may come apart due to a missing manufacturing step.
2024-05-31Smiths Medical ASD Inc.Smiths Medical became aware of an issue related to a potential for the patient outlet connector to loosen/detach from the paraPAC Plus P300 and P310 ventilators impacting the activ
2024-05-31Smiths Medical ASD Inc.There is a potential for inadvertent tidal volume knob movement from the original setting when set at high (1000-1500 mL) and low (70-150 mL) settings.
2024-05-31Smiths Medical ASD Inc.Smiths Medical became aware of an issue related to a potential for the patient outlet connector to loosen/detach from the paraPAC Plus P300 and P310 ventilators impacting the activ
2024-05-31Smiths Medical ASD Inc.There is a potential for inadvertent tidal volume knob movement from the original setting when set at high (1000-1500 mL) and low (70-150 mL) settings.
2024-02-07Smiths Medical ASD Inc.When a paraPAC plus ventilator is switched to the operating mode of VENTILATE, the ventilator may intermittently provide continuous positive gas flow instead of the intended cyclin
2024-02-07Smiths Medical ASD Inc.When a paraPAC plus ventilator is switched to the operating mode of VENTILATE, the ventilator may intermittently provide continuous positive gas flow instead of the intended cyclin
2021-07-15Smiths Medical ASD Inc.Two devices were labeled with the same serial number
2020-06-26Precision Valve & Automation,IncWhile operating the machine in "Run" mode an unexcepted event may occur during the error-checking for stepper movements and pressure values. The result of this event is a false ala