CAREvent ALS
O-Two Medical Technologies Inc · Model 01CV3100 · UDI-DI 07540195025110
Description
CAREvent ALS kit 01CV3100 contains a CAREvent ALS resuscitator and a pressure regulator. CAREvent ALS hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of providing artificial ventilation during respiratory and cardiac arrest. The CAREvent ALS delivers automatic ventilation with controlled flow rates, airway pressure, tidal volume and frequencies. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. In addition, CAREvent ALS allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2024-12-10 | Mercury Enterprises, Inc. dba Mercury Medical | Gas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and |
| 2024-08-30 | Mercury Enterprises, Inc. dba Mercury Medical | Manual resuscitator circuit flow controller may come apart due to a missing manufacturing step. |
| 2024-05-31 | Smiths Medical ASD Inc. | Smiths Medical became aware of an issue related to a potential for the patient outlet connector to loosen/detach from the paraPAC Plus P300 and P310 ventilators impacting the activ |
| 2024-05-31 | Smiths Medical ASD Inc. | There is a potential for inadvertent tidal volume knob movement from the original setting when set at high (1000-1500 mL) and low (70-150 mL) settings. |
| 2024-05-31 | Smiths Medical ASD Inc. | Smiths Medical became aware of an issue related to a potential for the patient outlet connector to loosen/detach from the paraPAC Plus P300 and P310 ventilators impacting the activ |
| 2024-05-31 | Smiths Medical ASD Inc. | There is a potential for inadvertent tidal volume knob movement from the original setting when set at high (1000-1500 mL) and low (70-150 mL) settings. |
| 2024-02-07 | Smiths Medical ASD Inc. | When a paraPAC plus ventilator is switched to the operating mode of VENTILATE, the ventilator may intermittently provide continuous positive gas flow instead of the intended cyclin |
| 2024-02-07 | Smiths Medical ASD Inc. | When a paraPAC plus ventilator is switched to the operating mode of VENTILATE, the ventilator may intermittently provide continuous positive gas flow instead of the intended cyclin |
| 2021-07-15 | Smiths Medical ASD Inc. | Two devices were labeled with the same serial number |
| 2020-06-26 | Precision Valve & Automation,Inc | While operating the machine in "Run" mode an unexcepted event may occur during the error-checking for stepper movements and pressure values. The result of this event is a false ala |