Description

The Lympha Press® Optimal Plus system is a multi-zone calibrated gradient pneumatic compression therapy system for treatment of lymphedema, venous insufficiency, venous stasis ulcers, dysfunction of the "muscle pump", lipedema, and edemas caused by trauma and immobility. The Lympha Press® Optimal Plus system consists of: • The console (sometimes called "compressor" or "pump") supplies air at regulated pressures to a compression garment that is worn over the area to be treated. • Hoses transfer the air from the console to each of the chambers in the compression garment. • The compression garment is fastened around the area to be treated. Each garment contains overlapping air chambers. These air chambers are filled with air from the console in sequence, applying a compressive massage. Once the entire area has been compressed, the console releases the pressure, and there is a brief pause. Then the process starts over again and is repeated until the treatment session is complete. The compress-and-release massage action stimulates lymphatic vessels in the treated area to take up and transport lymphatic fluid. The directional massage action encourages transport of the fluid towards the torso for collection by healthy lymphatics and return to the blood circulation. The directional compressive massage also helps reduce venous edema and stimulates venous return.

Recalls

DateFirmReason
2025-05-13Cardinal Health 200, LLCIncorrect software logic may cause frequent E1 errors (system high pressure). Issue may cause delay in treatment or therapy.
2025-05-13Cardinal Health 200, LLCIncorrect software logic may cause frequent E1 errors (system high pressure). Issue may cause delay in treatment or therapy.
2025-05-13Cardinal Health 200, LLCIncorrect software logic may cause frequent E1 errors (system high pressure). Issue may cause delay in treatment or therapy.
2023-04-14Stryker Sustainability SolutionsThrough complaint surveillance, it was identified that reprocessed Deep vein thrombosis (DVT) Compression Sleeves may be mislabeled and/or mispackaged.
2021-07-09Ortho8, Inc.EVEXIA LUXE DVT PREVENTION DEVICE is marketed without FDA clearance
2021-07-09Ortho8, Inc.CIRCUL8 LUXE DVT PREVENTION DEVICE is marketed without FDA clearance
2019-04-08Compass Health Brands (Corporate Office)Product design change did not receive proper premarket clearance and lacks a 510 (k)
2019-04-08Compass Health Brands (Corporate Office)Product design change did not receive proper premarket clearance and lacks a 510 (k)
2019-04-08Compass Health Brands (Corporate Office)Product design change did not receive proper premarket clearance and lacks a 510 (k)
2019-04-08Compass Health Brands (Corporate Office)Product design change did not receive proper premarket clearance and lacks a 510 (k)