FDA Device Intelligence
Home › MEDIC VISION - IMAGING SOLUTIONS LTD › SafeCT-29

SafeCT-29

MEDIC VISION - IMAGING SOLUTIONS LTD · Model 1.0 · UDI-DI 07290016836202

JAK Prescription
1
510(k) clearances
5,267
Adverse events (219 deaths)
865
Recalls
163
Facilities

Description

Medic Vision’s SafeCT-29 provides a vendor-neutral Radiation Dose Check functionality, in accordance with the Dose Check feature that is specified by the NEMA XR-25 Standard. The device is a software and hardware system which includes Computer, dedicated display and controls. The SafeCT-29 is interfaced to CT scanners that are not equipped with the Dose Check function. The device is connected to the CT Console video output via a standard video connector. The SafeCT-29 Computer’s internal video splitter captures the CT Console display video, in real time, without affecting neither the CT console itself nor its display. This analog video signal is digitized by a video grabber. The SafeCT-29 software analyzes the digital input video using OCR software continuously. The radiation dose information as calculated by the scanner and displayed to the CT operator is extracted and analyzed in real time. The SafeCT- 29 captures the video of the CT Console display in real time, without affecting neither the CT console itself nor its display and workflow. As specified by NEMA XR-25 Standard, the safeCT-29 notifies and alerts the CT operators, prior to a scan, if the estimated dose index is above the predefined values set by the operating group, practice, or organization. SafeCT-29 prevents continuing an over-the-limit scan unless dose levels are reconfirmed by the operator, in accordance with NEMA XR-29*.The device records the details of such events, including the operator details and decisions. This record is available to the user.

Recalls

DateFirmReason
2026-08-07Philips North America LlcPhilips has identified an unintended radiation issue with the Philips IQon, iCT, Ingenuity, and Brilliance CT 64 systems that could affect the performance of the equipment.
2026-08-07Philips North America LlcPhilips has identified an unintended radiation issue with the Philips IQon, iCT, Ingenuity, and Brilliance CT 64 systems that could affect the performance of the equipment.
2026-08-07Philips North America LlcPhilips has identified an unintended radiation issue with the Philips IQon, iCT, Ingenuity, and Brilliance CT 64 systems that could affect the performance of the equipment.
2026-08-07Philips North America LlcPhilips has identified an unintended radiation issue with the Philips IQon, iCT, Ingenuity, and Brilliance CT 64 systems that could affect the performance of the equipment.
2026-06-26Philips Healthcare (Suzhou) Co., Ltd.Potential of failing to trigger clinical scan during Bolus Tracking.
2026-06-11PHILIPS MEDICAL SYSTEMSThe clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result i
2026-06-11PHILIPS MEDICAL SYSTEMSThe clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result i
2026-06-11PHILIPS MEDICAL SYSTEMSThe clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result i
2026-03-26GE Medical Systems, LLCGE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with
2026-03-26GE Medical Systems, LLCGE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with