Home › Beijing Sano Lasers S&T Development Co., Ltd. › SANO

SANO

Beijing Sano Lasers S&T Development Co., Ltd. · Model SHE-ACP001-1 · UDI-DI 06973511890078

GEX
1
510(k) clearances
44,035
Adverse events (107 deaths)
201
Recalls
489
Facilities

Description

Cryojet Plus is intended to minimize pain and thermal injury during laser and dermatological treatments and for the temporary topical anesthetic relief for injections. And it shall be used by professionally trained medical operators. Cryojet Plus is composed of main body (including power supply system, control system, cooling system), power cable, supporting arm rod (a group of supporting rod, two support clips), wind tube, adapters, casters and other accessories. Control system consists of LCD screen display and control board, etc; Cooling system includes compressor, evaporator, radiator, fan, water tank; Power supply system is composed of power cable, filter and ON/OFF switch power. How It Works: Gaseous refrigerant is compressed into high-temperature and high-pressure gas by high-power compressor and sent to condenser for cooling. Refrigerant can produce cold air by condenser and evaporation system for skin cooling through conduction, evaporation and forced convection. Evaporator absorbs heat in air and vaporizes the heat, then heat is gaseous, then the gas is back to compressor and continue to be compressed. Thus cooling is done through such circulation. Defrosting system melts the frost inside evaporation system into liquid water and discharge the water through drain valve.

Recalls

DateFirmReason
2026-08-06Lutronic CorporationUtilizing higher fluences at 1064nm wavelength with current cryogen parameters may result in a spark/loud noise during treatment, potentially resulting in patient burn.
2026-05-05IPG Medical CorporationSoftware anomaly that causes a false display of error code 5018.
2026-02-27Olympus Corporation of the AmericasFollowing a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl
2026-02-27Olympus Corporation of the AmericasFollowing a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl
2026-01-27Lutronic CorporationReports of devices sparking/popping and potentially burning patients.
2025-12-15LEASEIR TECHNOLOGIES SLUThe console label for affected devices is missing the "DANGER" symbol.
2025-07-22LUMENIS, LTD.The potential for unsterilized product within finished product labeled as sterile.
2025-05-06Olympus Corporation of the AmericasPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or
2025-05-06Olympus Corporation of the AmericasPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or
2025-05-06Olympus Corporation of the AmericasPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or