Anchorfree
Beijing Anchorfree Technology Co., Ltd. · Model L808 · UDI-DI 06970441320019
Description
The diode laser system is a surgical device intended for use in dermatologic and general surgical procedure. It utilizes a semiconductor diode with invisible infrared radiation as a laser source (808 nm). The laser power is delivered to the treatment area via a laser handpiece. The emission laser is activated by a footswitch. The proposed system provides two working modes, which are standard hair removal mode (HR) and fast hair removal mode (FHR). They are different in the combination of frequency and fluence. Compared with HR mode, the FHR Mode (Fast Hair Removal) has low fluence and high repetition rate (10Hz). The treatment can be applied on different Fitzpatrick skin type, including I (White), II (White with pigment), III (Yellow), IV (Yellow with pigment), V (Brown) and VI (Black); in addition, the treatment can also be applied to different parts of the body, including Axillary, Chest, Arm, Back, Leg, Hairline, Cheek, Lip, Beard, and Bikini.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-06 | Lutronic Corporation | Utilizing higher fluences at 1064nm wavelength with current cryogen parameters may result in a spark/loud noise during treatment, potentially resulting in patient burn. |
| 2026-05-05 | IPG Medical Corporation | Software anomaly that causes a false display of error code 5018. |
| 2026-02-27 | Olympus Corporation of the Americas | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl |
| 2026-02-27 | Olympus Corporation of the Americas | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl |
| 2026-01-27 | Lutronic Corporation | Reports of devices sparking/popping and potentially burning patients. |
| 2025-12-15 | LEASEIR TECHNOLOGIES SLU | The console label for affected devices is missing the "DANGER" symbol. |
| 2025-07-22 | LUMENIS, LTD. | The potential for unsterilized product within finished product labeled as sterile. |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |