Home › LEICA BIOSYSTEMS NEWCASTLE LTD › BOND
BOND
LEICA BIOSYSTEMS NEWCASTLE LTD · Model PA0713-U · UDI-DI 05055331336330
NJT
Prescription
0
510(k) clearances
50
Adverse events (1 deaths)
92
Recalls
45
Facilities
Description
This reagent is for in vitro diagnostic use. H-Caldesmon (BSB-19) is intended to be used for the qualitative identification by light microscopy of human H-Caldesmon protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND-MAX, BOND-III or BOND-PRIME systems. The clinical interpretation of any staining or its absence should be complemented by morphological studies and proper controls and should be evaluated within the context of the patient’s clinical history and other diagnostic tests by a qualified pathologist.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-11-03 | GET TESTED INTERNATIONAL AB | Distribution without premarket approval/clearance. |
| 2025-08-11 | Agilent Technologies Denmark ApS | Their is the potential for weak staining which may result in false negative CD20 identification. |
| 2025-08-11 | Agilent Technologies Denmark ApS | Their is the potential for weak staining which may result in false negative CD20 identification. |
| 2025-08-11 | Agilent Technologies Denmark ApS | Their is the potential for weak staining which may result in false negative CD20 identification. |
| 2024-06-27 | Ventana Medical Systems, Inc. | Their is a potential for high background and off-target staining when using the monoclonal primary antibody which can result in false positive results. |
| 2021-07-30 | Leica Microsystems, Inc. | Product may not perform as specified in IFU. |
| 2021-07-15 | Cell Marque Corporation | Mouse Monoclonal Antibody labelled with an incorrect expiry date of 31 Dec 2023. The correct expiry date is 31 Dec 2022. If used beyond expiry, the material performance is likely t |
| 2019-11-18 | Leica Microsystems, Inc. | BOND Polymer Refine Detection kits (DS9800) were held out of refrigerated storage longer than specified which may exhibit suboptimal staining. |
| 2019-10-10 | Biocare Medical, LLC | Firm has identified product has no staining. If used, may result in invalid test results when used with controls in the clinical setting. Positive control would observe no staining |
| 2018-08-02 | Ventana Medical Systems Inc | Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur. |