FDA Device Intelligence
Home › NIDEK CO.,LTD. › Final Fit

Final Fit

NIDEK CO.,LTD. · Model 1.13 · UDI-DI 04987669101346

LZS Prescription
0
510(k) clearances
13,741
Adverse events (12 deaths)
29
Recalls
10
Facilities

Description

The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data)

Recalls

DateFirmReason
2021-10-21AMO Manufacturing USA, LLCAberrometer and precision laser systems are affected by a remote code execution vulnerability existing when the Microsoft Windows Print Spooler service is enabled, and improperly p
2017-02-01Nidek IncDuring treatment planning, the procedure was programmed with an unintended (wrong) correction.
2015-03-24Nidek IncMulti-stage treatment option for the EC-5000 Operator's Manual was not approved by the FDA.
2013-09-16Abbott Medical Optics, Inc.This corrective action will address an identified failure of the lamp and illumination system within the laser unit caused by an unexpected failure of a thyristor component on the
2013-09-16Abbott Medical Optics, Inc.This corrective action will address an identified failure of the lamp and illumination system within the laser unit caused by an unexpected failure of a thyristor component on the
2013-09-16Abbott Medical Optics, Inc.This corrective action will address an identified failure of the lamp and illumination system within the laser unit caused by an unexpected failure of a thyristor component on the
2013-09-16Abbott Medical Optics, Inc.This corrective action will address an identified failure of the lamp and illumination system within the laser unit caused by an unexpected failure of a thyristor component on the
2013-05-28Abbott Medical Optics, Inc.Under specific conditions, there is an unlikely potential to result in inadvertent laser firing of the laser.
2013-05-28Abbott Medical Optics, Inc.Under specific conditions, there is an unlikely potential to result in inadvertent laser firing of the laser.
2013-05-28Abbott Medical Optics, Inc.Under specific conditions, there is an unlikely potential to result in inadvertent laser firing of the laser.