Combination attachable delivery unit (YC-1800)
NIDEK CO.,LTD. · Model 17148-0000 · UDI-DI 04987669100318
Description
This combination delivery unit is need to comprise the combination system which enables you to emit the green laser beam or YAG laser beam while performing the observation with the slit lamp of the YAG laser system. This delivery unit is mounted on the slit lamp of the YAG laser system and connected to the NIDEK GREEN LASER PHOTOCOAGULATOR GYC-1000 using the connecting cable and fiber optic cable. The combination system allows selection between photocoagulation with the green laser beam (wavelength: 532 nm (continuous wave)) and photodisruption with the Nd:YAG laser beam (wavelength: 1064 nm (pulse laser)). In addition, they are selected easily by changing the optical path of the laser beam with the laser select lever, and various kinds of safety devices are integrated into the system so that only the selected laser beam is emitted. The GYC2SZ-3A is the only combination delivery unit that can be connected both to the NIDEK GREEN LASER PHOTOCOAGULATOR GYC-1000 and the NIDEK OPHTHALMIC YAG LASER SYSTEM YC-1800.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-06 | Lutronic Corporation | Utilizing higher fluences at 1064nm wavelength with current cryogen parameters may result in a spark/loud noise during treatment, potentially resulting in patient burn. |
| 2026-05-05 | IPG Medical Corporation | Software anomaly that causes a false display of error code 5018. |
| 2026-02-27 | Olympus Corporation of the Americas | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl |
| 2026-02-27 | Olympus Corporation of the Americas | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl |
| 2026-01-27 | Lutronic Corporation | Reports of devices sparking/popping and potentially burning patients. |
| 2025-12-15 | LEASEIR TECHNOLOGIES SLU | The console label for affected devices is missing the "DANGER" symbol. |
| 2025-07-22 | LUMENIS, LTD. | The potential for unsterilized product within finished product labeled as sterile. |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |
| 2025-05-06 | Olympus Corporation of the Americas | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or |