Description
The Wiltrom Spinal Fixation System is comprised of screws, rods, cross-link connector and associated surgical instruments that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. The Wiltrom Spinal Fixation System is designed to be used to stabilize the vertebrae through a posterior approach. The Wiltrom spinal implants are made of Ti-6Al-4V ELI material which complies with ISO 5832-3 and ASTM F136. Wiltrom Spinal Fixation System is provided nonsterile, and the implants are for single use only.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-05-28 | SEASPINE ORTHOPEDICS CORPORATION | Due to manufacturing error, polyaxial head may popoff from the screw intraoperatively following insertion. |
| 2026-05-22 | Innovasis, Inc | Pedicle screw system intended to provide immobilization/stabilization of spinal segments as adjunct to thoracic/lumbar/sacral spine fusion may have anti-torque instrument with unde |
| 2025-09-19 | Orthofix U.S. LLC | Polyaxial screws do not meet performance standards. |
| 2025-06-30 | SPINEART SA | Cannulated fenestrated polyaxial screws may be incorrectly labeled |
| 2025-06-30 | SPINEART SA | Cannulated fenestrated polyaxial screws may be incorrectly labeled |
| 2024-10-29 | SEASPINE ORTHOPEDICS CORPORATION | Due to manufacturing defects observed on Locking Caps that affect the ability for components to mate. |
| 2024-10-29 | SEASPINE ORTHOPEDICS CORPORATION | Due to manufacturing defects observed on Locking Caps that affect the ability for components to mate. |
| 2024-08-21 | XTANT Medical Holdings, Inc | Spinal fixation system implant screws marked "DNI" are not intended to be implanted and may not have been manufactured in accordance with released manufacturing specifications, and |
| 2024-03-15 | SPINEART SA | Due to receiving information regarding difficulties with the insertion of a setscrew inside a screw head. Issues involved, either: 1. The setscrew is not tightened to torque 2. The |
| 2024-02-28 | SEASPINE ORTHOPEDICS CORPORATION | Screw heads, of pedicle screw systems, have partial thread within the screw head that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. |