Collagen-Based Bone Filling Augmentation Material./ Product Overview: FOUNDATION is made of absorbable atelo-collagen. The atelo-collagen has been cross-linked by heat treatment in order to achieve biocompatibility. FOUNDATION is provided in bullet shapes. The collagen (liquid form) suspension is pored into a bullet shape mold. The design of the bullet shape is to permit easy placement into the extraction socket. It consists of fibrillar and heat-denatured atelo-collagen. Fibrillar atelo-collagen provides scaffolding for surrounding cells and the heat-denatured atelo-collagen stimulates infiltration of the cells in the product. Contents are sterile and non-pyrogenic.

Recalls

DateFirmReason
2018-08-16Collagen Matrix, Inc.There is a possibility that the product was packaged in the wrong box. Specifically, the product may have been placed inside a BioMend box instead of a BioMend Extend box. The only
2016-09-07Osteogenics Biomedical, Inc.The device has the potential to be packaged in the wrong product box.
2016-01-21Biomet France SARLCytotoxicity tests were not passed at 36 months. Use of Endobon-Xenograft Granules past 18 months of its specified shelf life may result in patient illness/injury.
2013-10-03Biomet 3i, LLCIndividual pieces of a batch of Biomet's Endobon Xenograft Granules 0.5 ML (Bovine Bone substitute) may have an incorrect label with the wrong batch number.
2013-03-28Integra LifeSciences CorporationDue to the process deviation, product lots in question may have been released with higher levels of pyrogens than permitted by the specifications for the products.
2013-03-28Integra LifeSciences CorporationDue to the process deviation, product lots in question may have been released with higher levels of pyrogens than permitted by the specifications for the products.
2013-03-28Integra LifeSciences CorporationDue to the process deviation, product lots in question may have been released with higher levels of pyrogens than permitted by the specifications for the products.
2012-10-25Kerr CorporationThe firm initiated the recall becaue disturbing the BioPlant product soon after it is placed may halt or delay the ossification process.
2012-01-11Cytophil, IncCytophil Corporation is recalling Periophil Biphasic Periophil Biphasic, Periobase Biphasic, and Periobone Biphasic because devices were inadvertently shipped after receiving an in
2010-05-14Ace Surgical Supply Co., Inc.Fast set 4% potassium sulfate solution may not be sterile. For customers who have used the Calcium Sulfate Hemihydrate kit without the Fast Set solution, then these potential risk