Home › SHIMADZU CORPORATION › CH-200
CH-200
SHIMADZU CORPORATION · Model 503-58100-27 · UDI-DI 04540217014491
10
510(k) clearances
85
Adverse events (1 deaths)
13
Recalls
34
Facilities
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-10-16 | SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION | Due to an issue (potential breakage) with the shaft for the mounting of the X-ray tube assembly that could potentially result assembly coming off the rotating shaft. |
| 2023-04-10 | SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION | Eight fixing bolts at the base of the X-ray ceiling tube column assembly may be loose or missing so service is required to install a cable, bracket, and label behind the bracket, i |
| 2018-06-29 | Siemens Medical Solutions USA, Inc | In rare cases of insufficient maintenance or high clinical workload, the first rope of the ceiling stand, which is designed to take the load, could break without triggering the saf |
| 2018-06-29 | Siemens Medical Solutions USA, Inc | In rare cases of insufficient maintenance or high clinical workload, the first rope of the ceiling stand, which is designed to take the load, could break without triggering the saf |
| 2014-10-28 | Summit Industries Inc. | The welds on J700 tube stands may be insufficient resulting in tube stand breakage, damage to the X-Ray machine, and/or patient or healthcare provider injury. |
| 2009-01-12 | Del Medical Systems Group | There is the potential for the supporting cable to become detached from the column causing the column to fall and possibly contact the patient or operator. |
| 2006-04-28 | Siemens Medical Solutions USA, Inc | Firm became aware that a potential pinch point can exist between the stop level and the safety catch when rotating the x-ray tube assembly. Risk of injury to operators fingers. |
| 2005-11-30 | Siemens Medical Solutions USA, Inc | screws on the rollers may become loose |
| 2005-03-10 | Del Medical Systems Group | The Phantom Portable X-Ray System Stand may have a suspect weld supporting the bracket holding the locking cylinder assembly. It the weld fails, the tubehead arm assembly could fa |
| 2004-09-30 | Fischer Imaging Corporation | Some VersaRad Systems have a faulty weld that may result in oil leakage. |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docsData compiled from public U.S. FDA sources (GUDID, 510(k)/PMA, MAUDE, recalls, establishment registration). Adverse-event reports are unverified and do not establish causation. Informational only — not medical, clinical, or regulatory advice.