diagnostic FTRD Set
Ovesco Endoscopy AG · Model 13 · UDI-DI 04260206311072
Description
The diagnostic FTRD Set is a novel tool for diagnostic and therapeutic full-thickness resection via flexible endoscope in colon and rectum • technology is based on OTSC System • enabling the endoscopist to resect all layers of suitable lesions including the serosa • enables a thorough pathological examination of e.g. motility disorders (e.g. Morbus Hirschsprung) • transection of the tissue happens after the defect has been closed completely • bowel lumen and abdominal cavity won't get into contact • it consists of the following three instruments: diagnostic FTRD (application cap with preloaded clip and integrated HF snare | endoscope sleeve, hand wheel and thread retriever | for colonoscopes) • FTRD Marking Probe (HF coagulation probe | marking of the target lesion in preparation of FTRD use | for detection and complete resection of the right tissue) • FTRD Grasper (specially designed grasping forceps | proper grip on the target tissue | precise retrieval of the sample into the application cap of the FTRD)
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
| 2022-07-29 | Hobbs Medical, Inc. | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs