NGMedical GmbH · Model BEE Cage cervical 9 x 14 mm 4° S · UDI-DI 04251631414865
Description
BEE Cages were especially adapted to the local anatomy to secure the surgical outcome at the best. The caudal side is flat, the cranial side is domed and the implant is formed conically from anterior to posterior. In the lateral view, the implant has a slightly lordotic form. The cage disposes of 4 pins on both bone facing surfaces, which serve the primary fixation. BEE implants are made of titanium alloy (Ti6Al4V) according to ASTM F 3001. BEE Cages are produced with selective laser melting (SLM) technique. It is not allowed to use BEE implants in contact with components of other manufacturers with the exception of bone graft substitutes or fillers.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2025-11-03 | Orthofix U.S. LLC | Labeling contains claims that are not consistently present. |
| 2023-07-12 | Medicrea International | There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch. |
| 2023-07-12 | Medicrea International | There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch. |
| 2023-07-12 | Medicrea International | There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch. |
| 2020-09-30 | XTANT Medical | Cervical Implants contain a label that incorrectly identifies the grade of titanium used. |
| 2013-10-07 | RTI Surgical, Inc. | As the result of a recent internal review of regulatory documents, we have determined that the 10 mm x 12 mm Webless C-Plus implants were incorrectly documented as meeting the requ |
| 2013-02-05 | SpineNet | The recall decision has been made because because it has recently been determined that the instructions for use (IFU) had certain statements that should have been removed prior to |
| 2012-06-15 | Exactech, Inc. | Exactech, Inc. initiated a recall of Equinoxe Replicator Plates, Equinoxe Locking Screws, Equinoxe Compression Screw Kits, Equinoxe Fracture Adapter Tray Screws, and Octane-C Inter |
| 2011-09-23 | Synthes USA (HQ), Inc. | LABELING CORRECTION - Following review of labeling and promotional materials associated with the Zero-P Implant system, it was found that the materials reference a study where PEEK |