AquaA
VIVONIC GmbH · Model AquaA2 900H · UDI-DI 04251285200432
Description
Additional membrane filtration unit (heat-disinfectable) for AquaA water purification system. AquaA2 900H for: AquaA 1800H & AquaA2 900H AquaA 1800H & AquaA2 900H & AquaHT The AquaA water purification system is a modular reverse osmosis unit intended for use with hemodialysis systems to remove organic and inorganic substances and microbial contaminants from the water used for treating hemodialysis patients or related therapies. This device is intended to be a component in a complete water purification system and is not a complete water treatment system. The reverse osmosis unit must be preceded by pre-treatment devices and may need to be followed by post-treatment devices as well, to meet current AAMI/ANSI/ISO and Federal (U.S.) standards.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2024-05-16 | Fresenius Medical Care Holdings, Inc. | Concentrate Flow was exceeding the maximum 19.9 bar set point. The standard default set point range is between 4 and 18.Error message (F020104, "concentrate pressure alarm limit ex |
| 2023-01-24 | Outset Medical, Inc. | An observed trend of high conductivity dialysate alarms in a hemodialysis system as a result of introducing a software tool into the manufacturing process. |
| 2022-06-21 | Fresenius Medical Care Holdings, Inc. | Internal ethemet cables are missing one or both ferrite cores therefore the electromagnetic compatibility of the device is not ensured |
| 2022-06-21 | Fresenius Medical Care Holdings, Inc. | Internal ethemet cables are missing one or both ferrite cores therefore the electromagnetic compatibility of the device is not ensured |
| 2022-06-16 | Fresenius Medical Care Holdings, Inc. | Internal ethernet cable may be misaligned, the cable jacket (insulation) could become compromised due to high temperature and result in the internal ethernet cable conducting elect |
| 2022-06-16 | Fresenius Medical Care Holdings, Inc. | Internal ethernet cable may be misaligned, the cable jacket (insulation) could become compromised due to high temperature and result in the internal ethernet cable conducting elect |
| 2021-08-03 | Fresenius Medical Care Holdings, Inc. | AquaBplus HF module on the AquaBplus 2000 osmosis system, an error in the US Installation Guideline instructed that 3-ring mains, instead of 2-ring mains, may be installed in combi |
| 2021-03-18 | Fresenius Medical Care Holdings, Inc. | AquaBplus HF module on the AquaBplus 2500 osmosis system, an error in the US Installation Guideline instructed that 3-ring mains, instead of 2-ring mains, may be installed in combi |
| 2020-09-01 | Fresenius Medical Care Holdings, Inc. | Incorrectly crimped connectors were installed on the main protective earth conductor on these machines. If the machine is moved or maintenance is performed, these crimp connections |
| 2014-04-24 | Mar Cor Purification | Mar Cor Purification manufactured Central Water Plant (CWP) reverse osmosis system, models 102, 104 and 106. This correction has been initiated due to a potential situation with a |