NATtrol™
ZEPTOMETRIX CORPORATION · Model NATtrol™ Flu/RSV/SARS-CoV-2 Swab Control Kit · UDI-DI 01220000260634
0
510(k) clearances
6
Adverse events
27
Recalls
57
Facilities
Description
NATtrol™ Flu/RSV/SARS-CoV-2 Swab Control Kit NATFRC-SW-IVD) is a qualitative in vitro diagnostic external control kit containing positive and negative controls intended to evaluate test performance of molecular assays which detect Influenza A, Influenza B, RSV B and SARS-CoV-2 nucleic acids.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-14 | TECHNO-PATH MANUFACTURING LTD. | A routine stability studies have identified a stability drift affecting the Ammonia (NH4+) analyte in specific lots of Multichem AE quality control material. Additional testing con |
| 2026-08-14 | TECHNO-PATH MANUFACTURING LTD. | A routine stability studies have identified a stability drift affecting the Ammonia (NH4+) analyte in specific lots of Multichem AE quality control material. Additional testing con |
| 2026-08-14 | TECHNO-PATH MANUFACTURING LTD. | A routine stability studies have identified a stability drift affecting the Ammonia (NH4+) analyte in specific lots of Multichem AE quality control material. Additional testing con |
| 2025-10-17 | TECHNO-PATH MANUFACTURING LTD. | Potential of negative recovery of the HBsAg analyte across two (2) lots of Multichem ID-B Positive Control when tested on the Alinity i platform. |
| 2025-10-17 | TECHNO-PATH MANUFACTURING LTD. | Potential of negative recovery of the HBsAg analyte across two (2) lots of Multichem ID-B Positive Control when tested on the Alinity i platform. |
| 2025-02-20 | Microbiologics Inc | The RSV target may give a late Ct value and could potentially not pass QC. |
| 2025-02-20 | Microbiologics Inc | The A549 human cell target (human cells for sample adequacy control) may give a late Ct value. |
| 2025-01-20 | Microbiologics Inc | Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed |
| 2025-01-20 | Microbiologics Inc | Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed |
| 2024-01-08 | Microbiologics Inc | The negative control was contaminated with one of the positive control pathogens (Norovirus). This would result in users getting a positive call for Norovirus when running the neg |