Home › SONOMED, INC. › VuMAX HD Ophthalmic Ultrasound System

VuMAX HD Ophthalmic Ultrasound System

SONOMED, INC. · Model VuMAX HD A/UBM · UDI-DI 00896100002248

IYO Prescription
1
510(k) clearances
6,553
Adverse events (17 deaths)
82
Recalls
350
Facilities

Description

The VuMAX HD Ophthalmic Ultrasound System is a non-invasive, active, bio-microscope (UBM) device for imaging ocular features for diagnostic purposes.The A-scan measures axial length (AXL), anterior chamber depth, lens thickness and vitreous length. The system operates on a computer-based platform. UBM capabilities include sulcus-to-sulcus, angle detail, high resolution, and motion picture settings. The system includes the multi-frequency ultrasound system base unit, 22" LCD, water-path probe with 35 MHz transducer, 10 MHz A-probe, keyboard and mouse, USB foot switch, immersion cups and user manual.

Recalls

DateFirmReason
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2022-01-24Volcano CorpMulti-Modality Touch Screen Modules (MM-TSM), which are bedside/secondary control units, used as part of Mobile IVUS systems, are missing the following labeling information: Unique
2021-11-04GE Healthcare, LLCThe firm identified that the Vscan Extend device will not power on because of depleted battery, due to the device not being turned off prior to battery removal or when being connec

Query this across every FDA database — by API.

Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.

Get your free API keyRead the docs