Picasso Clario Diode Laser

CAO GROUP, INC. · Model C810 · UDI-DI 00872320004422

GEX Prescription
10
510(k) clearances
44,032
Adverse events (107 deaths)
201
Recalls
485
Facilities

Description

Picasso Clario is a diode laser designed specifically for use by dental hygienists in perform dental hygiene procedures in the oral environment, within a dental office setting. The device features simplified a user interface with 5 presets for the most common hygiene procedures. Each preset allows for adjustment of settings based on the particular clinical case. The unit emits laser energy at 810nm at a power of up to 1.2 watts. The unit also features an visible red aiming beam. Laser energy is delivered via an optical fiber cable and single-use detachable tips. The laser is actuated by means of a wireless foot pedal.

Recalls

DateFirmReason
2026-08-06Lutronic CorporationUtilizing higher fluences at 1064nm wavelength with current cryogen parameters may result in a spark/loud noise during treatment, potentially resulting in patient burn.
2026-05-05IPG Medical CorporationSoftware anomaly that causes a false display of error code 5018.
2026-02-27Olympus Corporation of the AmericasFollowing a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl
2026-02-27Olympus Corporation of the AmericasFollowing a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperabl
2026-01-27Lutronic CorporationReports of devices sparking/popping and potentially burning patients.
2025-12-15LEASEIR TECHNOLOGIES SLUThe console label for affected devices is missing the "DANGER" symbol.
2025-07-22LUMENIS, LTD.The potential for unsterilized product within finished product labeled as sterile.
2025-05-06Olympus Corporation of the AmericasPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or
2025-05-06Olympus Corporation of the AmericasPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or
2025-05-06Olympus Corporation of the AmericasPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or