TC-510 Pressure Control Unit
MILLAR INC. · Model TC-510 · UDI-DI 00868924000229
Description
The TC-510 Pressure Control Unit is a passive interface between the pressure sensor of any standardized sensitivity Mikro-Tip® catheter and strain gauge pressure monitors or recording systems which supply bridge excitation voltage and have balance and calibration controls for full-bridge strain gauge pressure transducers. The TC-510 contains circuitry which facilitates monitor setup. In the STANDBY (0) position the TC-510 provides an electrical zero. In the 100 mmHg (13.3 kPa) position the TC-510 provides a signal equal to 100 mmHg (13.3 kPa) at a sensitivity of 5 μV/V/mmHg. The transducer is operational in the TRANSDUCER position and the TRANSDUCER BALANCE control allows balancing of the transducer
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2021-05-26 | Edwards Lifesciences, LLC | There is a potential that the pressure tubing may detach from the blood sampling system |
| 2015-11-13 | Edwards Lifesciences, LLC | Edward Lifesciences is recalling Intravascular (IV) Administration Sets due to the requirement of an additional FDA submission to support commercialization (clearance) of the devic |
| 2015-07-31 | Edward Lifesciences, Llc | Flow restriction issues in a trifurcated IV set included in the pressure transducer kits. A restriction of the flow of IV fluid would result in either an inability to prime the sys |