FDA Device Intelligence
Home › Spintech, Inc. › STAGE

STAGE

Spintech, Inc. · Model 2.4 · UDI-DI 00866463000496

LLZLNH Prescription
1
510(k) clearances
19,970
Adverse events (41 deaths)
561
Recalls
635
Facilities

Description

STAGE is a MR post-processing software medical device intended for use in the visualization of the brain. STAGE analyzes input data from MR imaging systems. STAGE runs within a VM environment on hardware that meets the minimum requirements. STAGE utilizes magnitude and phase data acquired with specific parameters to generate enhanced T1 weighted images, SWI images, susceptibility enhanced images, pseudo-susceptibility maps, true SWI images, MR angiography (MRA) images, simulated T2 images, simulated T2 FLAIR images, simulated dual inversion recovery (DIR) images, and maps of T1, R2*, and proton density (PD). CROWN, introduced in STAGE, reduces noise some of these outputs, enhancing SNR and/or reducing imaging time. STAGE is indicated for brain imaging. Maximum and minimum intensity projections of some of these outputs will also be provided. The STAGE outputs can be configured to match the conventional acquisition series in MR protocols (i.e. routine brain w/) in terms of contrast, orientation and resolution. STAGE should always be used in combination with at least one other conventional MR acquisition technique (e.g. T2 FLAIR). STAGE input data can be acquired within a range of collection parameters, within shorter echo acquisitions allowing for less susceptibility affects and higher anatomic signal at the air tissue interface or with longer echo times for higher susceptibility effects around blood products and iron sources.

Recalls

DateFirmReason
2026-09-05INTELERAD MEDICAL SYSTEMS INCORPORATEDFollowing a Chromium-based web-browser, report and displayed images may not match.
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-22Merge Healthcare, Inc.Software issue may cause measurements to be displayed inaccurately.
2026-07-22FUJIFILM Healthcare Americas CorporationSoftware issue may cause the ruler measurement to be inaccurate.
2026-06-30Merge Healthcare, Inc.Merge Healthcare has identified a potential issue that may cause thumbnails from a previously opened patient study to be displayed in the Thumbnail Bar while a different patient st

Query this across every FDA database — by API.

Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.

Get your free API keyRead the docs
Data compiled from public U.S. FDA sources (GUDID, 510(k)/PMA, MAUDE, recalls, establishment registration). Adverse-event reports are unverified and do not establish causation. Informational only — not medical, clinical, or regulatory advice.