FDA Device Intelligence
Home › RADLINK, INC. › Radlink PH GPS Bracket

Radlink PH GPS Bracket

RADLINK, INC. · Model PH BRACKET · UDI-DI 00864908000131

MQB
10
510(k) clearances
1,282
Adverse events (11 deaths)
195
Recalls
126
Facilities

Description

The PH GPS Bracket is comprised of Radlink proprietary software and hardware to duplicate Radlink user interface onto Philips reference monitor of the MVS utilizing a switch box that shifts the video signal between Philips and Radlink on the reference monitor. Not only does Radlink solution expand the field of view of Philips C-Arms utilizing Pano function, but it also facilitates intra-operative image analysis by assisting surgeons to evaluate acetabular cup position, limb length discrepancy, and femoral offset during Total Hip Arthroplasty. The PH GPS Bracket comes with software features such as image stitching and Surgeon’s Checklist™ software that provides surgeons with real-time feedback on orthopedic implant component positioning. Pre-operative images can be viewed on the device during surgery, which surgeons can use to reference against the intra-operative images captured during the procedure.

Recalls

DateFirmReason
2026-05-01Philips North America LlcSystem was delivered without the required Seismic kit for Wall Stand VS2, which is designed to prevent damage and ensure stability of the Wall Stand VS2 during seismic events.
2025-10-01Philips Medical Systems DMC GmbHPhilips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/p
2023-05-19Philips North America LlcThere is a software login in issue that may prevent the user from logging in.
2021-09-22Philips HealthcareThe Aleva monitor requires certain labels to be applied, some of which are required by FDA Electronic Product Radiation Control performance standards. This includes the Radiation W
2021-03-11LIEBEL-FLARSHEIM COMPANY LLCFailure to comply with the performance standard for fluoroscopy systems. Per 21 CFR 1020.32(k)(6), the displayed AKR and cumulative air kerma shall not deviate from the actual valu
2021-02-05Canon Medical System, USA, INC.The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.
2020-12-08Canon Medical System, USA, INC.System table may tilt because the bolts that fasten the vertical column and the table top tilting drive unit may become loose.
2020-04-06Siemens Medical Solutions USA, IncIt was determined that in rare cases persons can receive low dose of unintended radiation. The system performed exposures without the exposure button being pressed. Exposure will
2020-03-03Canon Medical System, USA, INC.Bolts holding the longitudinal movement of catheterization tables may be loose, which may lead to table surface/top tilting.
2020-01-07Palodex Group OySlow degradation of plastic insulation used in the PSU DC plug of the DIGORA Optime, Scan eXam, Express, GXPS-500 systems may result in short circuiting which may cause heating and

Query this across every FDA database — by API.

Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.

Get your free API keyRead the docs