The Sanitas™ Clinical Care Platform is a software system that collects patient physiological data (such as blood pressure and blood sugar levels) for transmission to a secure central storage server, which can be accessed by healthcare professionals for analysis and intervention using standard digital communication technologies and protocols. These data are also available to the patient for viewing purposes and as an aid in maintaining wellness regiments. The Sanitas™ Clinical Care Platform is an accessory software application that is used by patients in non-clinical settings (e.g. home), to collect, record and transmit their physiological information to a remote secure server. Stored data is accessible by healthcare professionals for analysis and intervention using standard digital communication technologies and protocols. The Sanitas Clinical Care Platform is also intended to be used in combination with a variety of external vital sign devices. The Sanitas Clinical Care Platform does not measure, interpret or make any decisions on the data that it conveys. It is not intended as a replacement for the oversight of healthcare professionals nor does it provide "real-time" or emergency monitoring.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-07-20 | Midmark Corporation | A communication anomoly may result in incorrect electrocardiogram waveforms of a patient and an inaccurate beats-per-minute calculation. |
| 2024-07-19 | Biointellisense Inc. | Software anomaly causing the skin temperature measurement accuracy to be slightly out of specification. |
| 2021-01-08 | Nihon Kohden America Inc | Incorrect Date Stamp or No Data Transfer on Telemetry Receiver and Transmitter. |
| 2020-05-21 | Vitalconnect Inc. | A healthcare provider (HCP) noticed a patient had a lowered historic SpO2 reading that the software should have triggered a notification to the care team, but no notification was f |
| 2017-05-15 | Boston Scientific Corporation | The device history record (DHR) was missing its test documentation for final HIPOT (high potential) electrical testing. |
| 2017-03-02 | Philips Visicu | eCareCoordinator (eCC) is intended for use in data aggregation, patient interaction facilitation, storage and clinical information management with independent physiological device |
| 2016-03-10 | Philips Visicu | The adherence check generates a software error. Two issues occur as a result of the software error: 1) No adherence flag is generated for that day; 2) No task is generated for the |
| 2012-02-24 | BRAEMAR, INC. | Braemar has recently became aware of a battery related incident that occurred with EWT battery packs that are used in a Braemer ER920W wireless event monitor and Fusion device. Th |
| 2011-05-02 | BRAEMAR, INC. | Braemar Inc., became aware of a battery related incident that occurred with an Able battery pack being used in a Braemar ER920W wireless event monitor. The event did not result i |
| 2007-12-13 | Lifesync Corporation | LifeSync Wireless ECG System - Intermittent failure when using LS-202 and LS-232 LeadWear in conjunction with LS-41245 and LS-41285 Adaptors. The out of box failure manifests as a |