Sistema diagnóstico de rayos X dental diseñado para fijación permanente en una ubicación con objeto de generar y controlar los haces de rayos X. Registra el patrón de absorción de los haces de rayos X utilizado para exámenes radiográficos dentales generales y rutinarios que implican el diagnóstico y tratamiento (p. ej., quirúrgico o intervencionista) de afecciones de las piezas dentales, mandíbula y cavidad bucal. El sensor se coloca fuera de la boca, con el propósito de visualizar toda el área de esta y mostrar las piezas dentales, tanto en la mandíbula superior como en la inferior. Los datos proceden de imágenes analógicas y que se digitalizan posteriormente o bien de imágenes digitales.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-06-19 | DIGIMED CO., LTD | Some DIOX-602 units currently in use within the United States do not meet the minimum SSD requirement of 18 cm. |
| 2017-07-14 | Panoramic Rental Corp. | The lift motor used to raise and lower the overhead chassis will wear if not properly maintained according to the maintenance schedule. |
| 2016-08-19 | Panoramic Rental Corp. | Panoramic Corporation is performing a voluntary Medical Device Correction on certain PC-1000 X-ray systems due to the potential for a safety nut to be ineffective, which could resu |
| 2016-07-18 | Aribex Inc | Firm received customer complaints where end users reported that Nomad Pro and Pro 2 handsets had appeared to "overheat", "melt", "smoke" and/or "ignite." Investigation found that |
| 2016-07-18 | Aribex Inc | Firm received customer complaints where end users reported that Nomad Pro and Pro 2 handsets had appeared to "overheat", "melt", "smoke" and/or "ignite." Investigation found that |
| 2015-06-04 | Panoramic Rental Corp. | Jackscrew nut part failure potentially leading to device malfunction and patient/operator injury. |
| 2014-08-12 | Gendex Corp | Two (2) failures of the spring link components within the articulated arm assembly. The spring links broke during normal assembly process for the articulated arm during first cycle |
| 2014-01-24 | Carestream Health Inc. | Carestream received problem reports relating to apparent early failure of Kodak 2X00 Intraoral X-ray device arms leading to arm breakage. |
| 2014-01-24 | Carestream Health Inc. | Carestream received problem reports relating to apparent early failure of Kodak 2X00 Intraoral X-ray device arms leading to arm breakage. |
| 2014-01-14 | Instrumentarium Dental, PaloDEx Group Oy | Instrumentarium Dental has delivered a number of FOCUS 3.0 Intraoral X-ray units in November 2013 with a potential flaw in the mounting hardware. A number of wall mount units were |