Continuous ECG Platform
VIVALNK, INC. · Model VV350 · UDI-DI 00860008259233
Description
VV330 Continuous ECG Platform is a wireless recording system intended for use by healthcare professionals for record and display of physiological data within healthcare settings or at home. This includes electrocardiogram (ECG), accelerometer data, R-R Interval and heart rate. Data is transmitted wirelessly to a separate location (such as a mobile phone) for storage and display. The VV330 Continuous ECG Platform can be configured by Authorized Persons to modify or merge or ignore any of the operational alerts, but not to set new alerts related to physiological data. The device is not intended to be used on critical care patients and is intended to supplement vital signs recording for later viewing by healthcare professionals, not to replace current standards of care. The device is an ambulatory, continuous recording system intended for use on general care patients and on patients who are 18 years of age or older.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-07-20 | Midmark Corporation | A communication anomoly may result in incorrect electrocardiogram waveforms of a patient and an inaccurate beats-per-minute calculation. |
| 2024-07-19 | Biointellisense Inc. | Software anomaly causing the skin temperature measurement accuracy to be slightly out of specification. |
| 2021-01-08 | Nihon Kohden America Inc | Incorrect Date Stamp or No Data Transfer on Telemetry Receiver and Transmitter. |
| 2020-05-21 | Vitalconnect Inc. | A healthcare provider (HCP) noticed a patient had a lowered historic SpO2 reading that the software should have triggered a notification to the care team, but no notification was f |
| 2017-05-15 | Boston Scientific Corporation | The device history record (DHR) was missing its test documentation for final HIPOT (high potential) electrical testing. |
| 2017-03-02 | Philips Visicu | eCareCoordinator (eCC) is intended for use in data aggregation, patient interaction facilitation, storage and clinical information management with independent physiological device |
| 2016-03-10 | Philips Visicu | The adherence check generates a software error. Two issues occur as a result of the software error: 1) No adherence flag is generated for that day; 2) No task is generated for the |
| 2012-02-24 | BRAEMAR, INC. | Braemar has recently became aware of a battery related incident that occurred with EWT battery packs that are used in a Braemer ER920W wireless event monitor and Fusion device. Th |
| 2011-05-02 | BRAEMAR, INC. | Braemar Inc., became aware of a battery related incident that occurred with an Able battery pack being used in a Braemar ER920W wireless event monitor. The event did not result i |
| 2007-12-13 | Lifesync Corporation | LifeSync Wireless ECG System - Intermittent failure when using LS-202 and LS-232 LeadWear in conjunction with LS-41245 and LS-41285 Adaptors. The out of box failure manifests as a |