FDA Device Intelligence
Home › Endoglow, LLC › GreenEgg

GreenEgg

Endoglow, LLC · Model EP1000-30 · UDI-DI 00860001161618

EXX Prescription
0
510(k) clearances
10
Adverse events
1
Recalls
41
Facilities

Description

DEVICE DESCRIPTION The GreenEgg™ is a sterile, single-use hand held, non-powered pelvic manipulator used for surgical manipulation and transillumination of the rectum and/or vagina. The 30mm diameter polymer tip fluoresces when viewed under a near infrared system PACKAGING CONTENTS A single GreenEgg™ device is CSR wrapped and placed inside a Tyvek header bag in sterile fashion. INDICATIONS FOR USE The EndoGlow GreenEgg™ manipulator is indicated to provide manipulation of the vaginal or rectum during minimally invasive surgical procedures. When viewed with the NIR camera system of a laparoscope or surgical robot, the GreenEgg™ will fluoresce providing transillumination DIRECTIONS FOR USE Confirm exp date. Remove bag from box, open the bag using sterile technique. Transfer the contents of the bag (CSR blue wrapped GreenEgg™ manipulator) to sterile field Once introduced to the field, the CSR wrap can be removed from the device and discarded. The GreenEgg™manipulator is ready for use Insert the GreenEgg™ manipulator into the vagina or rectum and proceed with surgical procedure CONTRAINDICATIONS The GreenEgg™ is a nonpowered, handheld manipulator, do not use it outside of standard surgical protocol or techniques WARNINGS Contents supplied sterile. Do not use if sterile barrier is damaged Do not use the GreenEgg™ if the device has been opened or damaged CAUTION U.S. Federal law restricts this device to sale by or on the order of a physician STORAGE Store at room temp, avoid extreme temps DISPOSAL Dispose of in accordance with all applicable Federal, State, and local Medical/ Hazardous waste practices REUSE PRECAUTION STATEMENT For single use only: Do not reuse, re-process or re-sterilize. Do not reuse, reprocess, or re-sterilize. Attempting to re-sterilize and reuse the product may diminish its intended performance in transilluminating tissue, reducing its effectiveness. To ensure optimal results and patient safety, a new product must be used for each procedure.

Recalls

DateFirmReason
2009-04-09Marina Medical Instruments Inc.Marina Medical, Sunrise, FL initiated recall of 46 different 350 series devices and 47 different 270 series products because the material used to manufacture the products was not p

Query this across every FDA database — by API.

Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.

Get your free API keyRead the docs