FDA Device Intelligence
Home › Nipro Vascular Innovations Americas, Inc. › TVC Integrated Imaging System™

TVC Integrated Imaging System™

Nipro Vascular Innovations Americas, Inc. · Model TVC-MC9i · UDI-DI 00857595006623

IYOOGZ
10
510(k) clearances
6,627
Adverse events (17 deaths)
83
Recalls
353
Facilities

Description

TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. This model of TVC Imaging System is designed to be installed in the catheterization laboratory and minimize usage of space. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32). Indications for Use: 1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.

Recalls

DateFirmReason
2026-08-06Volcano CorpSoftware system may associate image data from one patient with another patient's record, potentially resulting in incorrect diagnosis or treatment.
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2026-03-02Civco Medical Instruments Co. Inc.There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified
2022-01-24Volcano CorpMulti-Modality Touch Screen Modules (MM-TSM), which are bedside/secondary control units, used as part of Mobile IVUS systems, are missing the following labeling information: Unique