A manual surgical instrument that cuts cancellous bone by manual actuation of the 8mm cutting tip. The cap contains a barbed nozzle that connects to standard sized suction tubing (tube with an ID of 6–10 mm) to connect to a vacuum source, wherein the vacuum source has a static maximum pressure between 150 mmHg and 300 mmHg. The proposed device can be connected to a waste canister that leads to standard operating room wall suction or to an external pump. With the device connected to a vacuum source, when actuated in bone the cutting tip carves, scrapes and cuts cancellous bone and collects the bone graft inside the handle. The suction pulls the bone and bone marrow from the cutting tip and into the bone reservoir inside the handle. The cap contains a filter that prevents material from escaping the handle into the suction system by utilizing a physical sieve to keep bone particulate in the handle. After harvesting, the bone graft can be retrieved from the handle.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-20 | Bard Peripheral Vascular Inc | Breast biopsy and tissue removal system may experience the following errors: 1) Probe calibration and /or handheld driver failure (code HH01-00020009) , 2) Pressure sensor (code E |
| 2026-06-01 | Argon Medical Devices, Inc | Kits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility. |
| 2026-06-01 | Argon Medical Devices, Inc | Kits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility. |
| 2026-06-01 | Argon Medical Devices, Inc | Kits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility. |
| 2025-12-15 | Hologic, Inc | Presence of particulates in affected devices that can be deposited into breast tissue during use. |
| 2025-01-15 | Hologic, Inc | Devices presented a condition in which the inner needle separated from the hub and produced a longer throw of the inner needle or dislodgement. |
| 2024-09-30 | Bard Peripheral Vascular Inc | Disposable biopsy instruments were potentially manufactured missing the backend notch retention feature on the needle that results in inadequate securing of the needle inside the d |
| 2024-07-02 | Argon Medical Devices, Inc | Holes have been identified in biopsy instrument packaging trays compromising the sterile barrier, which may lead to cross contamination, or the introduction of micro-organisms into |
| 2023-11-08 | Bard Peripheral Vascular Inc | The internal diameter of the coaxial cannula may be smaller or larger than the external diameter of the biopsy needle, and the length of the cannula may exceed the stated length on |
| 2023-08-10 | Bard Peripheral Vascular Inc | Diameter mismatch between coaxial and biopsy needle (cutting cannula) in disposable core biopsy instrument kits, where the coaxial cannula inner diameter prohibits the biopsy needl |