REAADS Anti-Phosphatidylserine IgG/IgM Semi-Quantitative Test Kit (96 Well)
CORGENIX MEDICAL CORPORATION · Model 030-001 · UDI-DI 00855360006090
Description
INTENDED USE Detection and semi-quantitation of anti-phosphatidylserine antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use. SUMMARY AND EXPLANATION OF THE ANTI-PHOSPHATIDYLSERINE TEST High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (i.e., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. These antibodies have been associated with an increased risk for recurrent arterial and venous thrombotic events, thrombocytopenia and fetal loss. Phosphatidylserine is a more physiologically relevant phospholipid due to its presence in cell membranes of endothelial cells and platelets. PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in phosphatidylserine coated microwells. β2-glycoprotein I is provided in the sample diluent. After the removal of unbound serum/plasma proteins by washing, antibodies specific for human IgG or IgM, labeled with horseradish peroxidase (HRP), are added forming complexes with the phosphatidylserine bound antibodies. Two enzyme-conjugated antibody solutions are provided, one specific for human IgG antibodies and one specific for human IgM antibodies. Following another washing step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-phosphatidylserine (aPS) antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided for both IgG and IgM antibody concentrations expressed in GPS or MPS units. Control and patient results are determined from the calibration curve. Refer to Package Insert.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2023-02-28 | Bio-Rad Laboratories, Inc. | APLS IgM reagent kits were packaged with the incorrect conjugate, which could lead to an increase in false-positive and false-negative results. |
| 2016-10-21 | Euro Diagnostica AB | Incorrectly labeled Manufactured by DiaSorin, The correct term should be Distributed by DiaSorin. |
| 2016-10-21 | Euro Diagnostica AB | Incorrectly labeled Manufactured by DiaSorin, The correct term should be Distributed by DiaSorin. |
| 2012-08-02 | Phadia US Inc | Customers were not following the labeled assay procedure. This was due to a letter issued to them in 2004 from Phadia GmbH, which indicated that customers could omit the pre-wash s |
| 2008-08-27 | Calbiotech Inc | The recall has been initiated due to the "For Export Only" labeling found on some Calbiotech, Inc. ELISA kits. Although there is no potential health hazard related to this recall, |
| 2006-07-18 | Louisville Apl Diagnostics Inc | Product mislabeled; outer container labeled with incorrect lot number. |
| 2006-01-11 | Thera Test Laboratories, Inc. | The specimen diluent contained in the kits was contaminated with a fungal growth. Also, a portion of kit lot 09055514 was shipped without the Data Sheet, part #201-204. |
| 2005-10-06 | Louisville Apl Diagnostics Inc | Mislabeling: Errors (control values) identified in the QC Fact Sheet for a specific lot of APhL HRP IgG and IgM test kits. |
| 2005-10-06 | Louisville Apl Diagnostics Inc | Mislabeling: Errors (control values) identified in the QC Fact Sheet for a specific lot of APhL HRP IgG and IgM test kits. |
| 2005-10-06 | Louisville Apl Diagnostics Inc | Mislabeing : Errors (control values) identified in the QC Fact Sheet for a specific lot of APhL HRP IgG and IgM test kits. |