Home › ACTUATED MEDICAL, INC. › GripTract-GI Endoscopic Tissue Manipulator
GripTract-GI Endoscopic Tissue Manipulator
ACTUATED MEDICAL, INC. · Model GT-CL130 · UDI-DI 00850458007171
FDF
Prescription
1
510(k) clearances
84,519
Adverse events (63 deaths)
25
Recalls
77
Facilities
Description
GripTract-GI Model GT-CL130 is a single-use, non-sterile, endoscope accessory intended to assist in positioning the distal end of an endoscope from the mucosal surface and assist with optical visualization, diagnosis, and endoscopic treatment. GripTract Model GT-CL130 is indicated for use in the large intestine with any standard endoscope with a distal tip outer diameter of 12.8 – 13.3 mm and a working length of 130 -133 cm.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2024-01-11 | Olympus Corporation of the Americas | Specific repaired colonovideoscopes were assembled without an adhesive which protects them from certain physical conditions such as high levels of vibration, fluctuation in tempera |
| 2024-01-11 | Olympus Corporation of the Americas | Specific repaired colonovideoscopes were assembled without an adhesive which protects them from certain physical conditions such as high levels of vibration, fluctuation in tempera |
| 2024-01-11 | Olympus Corporation of the Americas | Specific repaired colonovideoscopes were assembled without an adhesive which protects them from certain physical conditions such as high levels of vibration, fluctuation in tempera |
| 2023-10-16 | Aizu Olympus Co., Ltd. | Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in |
| 2023-10-16 | Aizu Olympus Co., Ltd. | Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in |
| 2023-10-16 | Aizu Olympus Co., Ltd. | Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in |
| 2023-10-16 | Aizu Olympus Co., Ltd. | Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in |
| 2023-10-16 | Aizu Olympus Co., Ltd. | Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in |
| 2023-10-02 | Olympus Corporation of the Americas | Sterilization failures when devices are sterilized per the Reprocessing Manual due to lack of drying time for the endoscope channel. |
| 2023-09-25 | Aizu Olympus Co., Ltd. | Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endo |