Home › Rhythm Healthcare, LLC › Rhythm Healthcare, LLC
Rhythm Healthcare, LLC
Rhythm Healthcare, LLC · Model LM5BA · UDI-DI 00850083102944
CAW
Prescription
1
510(k) clearances
52,921
Adverse events (527 deaths)
44
Recalls
87
Facilities
Description
The Oxygen Concentrator is a portable concentrator which could utilize a molecular sieve and pressure swing adsorption to produce oxygen. The device can separate nitrogen by absorbing through the molecular sieve when the room air enters the device and allows the enriched oxygen to be collected. The device could provide approximately 90~96% of oxygen to patients on a continuous flow basis at a rate of 1L/min to 5L/min.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-02-04 | 3B Medical, Inc. | Devices which did not meet internal quality specifications were inadvertently distributed. |
| 2025-10-07 | Philips Respironics, Inc. | Certain serial numbers of the SimplyGo Mini standard battery kit contain a defective chip which can lead the battery to either fail to charge or lose voltage output when in use in |
| 2025-05-08 | Ohio Medical Corporation | Erroneous calibration values, potentially resulting in: as the device ages, oxygen purity will gradually decrease to the point where the device alarms to indicate low oxygen purit |
| 2025-04-11 | Medical Depot Inc. | Potential for DC Power Supply housing to become hot to the touch and deform the plastic housing. |
| 2024-12-09 | JIANGSU JUMAO X-CARE MEDICAL EQUIPMENT CO LTD | Oxygen concentrator may melt or catch on fire during use. |
| 2024-10-04 | Caire, Inc. | Potential failure of affected units to recharge the battery of the oxygen concentrators. |
| 2024-10-04 | Caire, Inc. | Potential failure of affected units to recharge the battery of the oxygen concentrators. |
| 2024-10-04 | Caire, Inc. | Potential failure of affected units to recharge the battery of the oxygen concentrators. |
| 2024-10-04 | Caire, Inc. | Potential failure of affected units to recharge the battery of the oxygen concentrators. |
| 2023-03-09 | DeVilbiss Healthcare LLC | The instruction manual is being replaced with an updated version that is in alignment with labeling requirements specified in the IEC-60101-1 standard. |